clc, clear all;
frequency = 50;
omega = 2*pi*frequency;
vbase = 400; %vbase is 400v
sbase = 10000; %base power is 10kVA
rbase = vbase^2/sbase;
igbt_ron_pu = 1e-3/rbase;
igbt_snb_pu = 1e6/rbase;
vdc = 400*1.88;
Tsc = 100e-6;
fsw = 1/Tsc;
vref_rms = 300*(0.707*sqrt(3));
vc_l = 0.03*rbase;
vc_c = 0.13*rbase;
vi_l = 0.3*rbase;
vi_c = 0.024*rbase;
vi_lg = 0.035*rbase;
si_real = 0.1*sbase;
si_imag = 0*sbase;
%% Stable case
%Current controlled inverter parameters
Lf = 4e-3;%H
Lf_r = 0.3;%Ohm
Cf = 2e-5;%F
Cf_r = 1;%Ohm
Lg = 0.24e-3;%H
kpgi = 5;
krgi = 200;
%Voltage Controlled VSC Controller
L_fv = 1.5e-3;%H
C_gv = 1.5e-3;%F
krv = 100;
kpv = 0.1;
kpi = 8;
%Transmission Line parameters
R_line = 0.013*rbase; %Ohm
L_line = 0.003*rbase/omega; %H
%% Unstable case
%Current controlled inverter parameters
kpgi = 15; %unstable case 15
krgi = 600; %unstable case 600