Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathautoPL-02.03-1530.ahk
163 lines (153 loc) · 4.85 KB
/
autoPL-02.03-1530.ahk
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
#NoEnv ; Recommended for performance and compatibility with future AutoHotkey releases.
#Warn ; Enable warnings to assist with detecting common errors.
SendMode Input ; Recommended for new scripts due to its superior speed and reliability.
SetWorkingDir %A_ScriptDir% ; Ensures a consistent starting directory.
SetTitleMatchMode 2
#SingleInstance force
#InputLevel, 3
#Persistent
;some comments may be outdated
;these automatically run when the script first starts and stick until overwritten
;PL1 (8W)
run %comspec% /k ""C:\Program Files (x86)\Intel\Intel(R) Extreme Tuning Utility\Client\xtucli.exe" -t -id 48 -v 8",,hide
;PL2 (12W)
run %comspec% /k ""C:\Program Files (x86)\Intel\Intel(R) Extreme Tuning Utility\Client\xtucli.exe" -t -id 47 -v 12",,hide
;PL2 time window (20 seconds), default on most devices is 32 seconds
run %comspec% /k ""C:\Program Files (x86)\Intel\Intel(R) Extreme Tuning Utility\Client\xtucli.exe" -t -id 66 -v 20",,hide
;core undervolt (-50 mV) - doesn't work on all devices and may be unstable
run %comspec% /k ""C:\Program Files (x86)\Intel\Intel(R) Extreme Tuning Utility\Client\xtucli.exe" -t -id 34 -v -50",,hide
;iGPU undervolt (-50 mV) - doesn't work on all devices and may be unstable
run %comspec% /k ""C:\Program Files (x86)\Intel\Intel(R) Extreme Tuning Utility\Client\xtucli.exe" -t -id 100 -v -50",,hide
;cache undervolt (-50 mV) - doesn't work on all devices and may be unstable
run %comspec% /k ""C:\Program Files (x86)\Intel\Intel(R) Extreme Tuning Utility\Client\xtucli.exe" -t -id 79 -v -50",,hide
global cput0 := 50 ;initializing the value
SetTimer, readlog, 60000 ;60 second timer
readlog:
global linenum = 93 ;SET THIS FOR YOUR DEVICE
gosub readtemp2 ;read last sample
global cput1 := regout
gosub readtemp ;read current sample
global cput2 := regout
if (cput2 >= 75) ;if 75+°C, jump to PLs
{
global cput := cput2
gosub PL
}
else
sleep 10
gosub readtemp
global cput3 := regout
if (cput3 >= 75)
{
global cput := cput3
gosub PL
}
gosub readtemp
global cput4 := regout
if (cput4 >= 80)
{
global cput := cput4
gosub PL
}
gosub readtemp
global cput5 := regout
if (cput5 >= 80)
{
global cput := cput5
gosub PL
}
else
sleep 10
global cput := Round(((cput0 + cput1 + cput2 + cput3 + cput4 + cput5)/6), 0) ;average the values
if (cput = 0)
cput := 65
else
sleep 10
tooltip %cput%
sleep 1000
tooltip
gosub PL
return
PL:
if ((abs(cput0 - cput) >= 5) && cput < 80) ;if difference from old is < 5
{
if (cput >= 75 && cput < 80) ;temp between 75 and 79
{
global pl1 := 5
global pl2 := 6
plfunc() ;run xtucli with pl1 and pl2
}
else if (cput < 75 && cput >= 70)
{
global pl1 := 6
global pl2 := 7.5
plfunc()
}
else if (cput < 70 && cput >= 65)
{
global pl1 := 6.5
global pl2 := 8
plfunc()
}
else if (cput < 65 && cput >= 60)
{
global pl1 := 7
global pl2 := 10
plfunc()
}
else if (cput < 60 && cput >= 55)
{
global pl1 := 8
global pl2 := 11
plfunc()
}
else if (cput < 55 && cput >= 50)
{
global pl1 := 9
global pl2 := 12
plfunc()
}
else if (cput < 50)
{
global pl1 := 10
global pl2 := 13
plfunc()
}
global cput0 := cput ;create old temp value
}
else if ((abs(cput0 - cput) >= 5) && cput <= 80)
{
global pl1 := 4.5
global pl2 := 5
plfunc()
tooltip 80 ;1 second tooltip displaying '80'
sleep 1000
tooltip
global cput0 := cput
}
else ;if absolue value < 5
{
global cput0 := (cput + 1) ;increment by one to increase chance of next trigger
sleep 1000
}
return
readtemp: ;CPU-Z takes around 3 seconds to generate the report - this runs and reads after 5 secs
run "C:\Program Files\CPUID\CPU-Z\cpuz.exe" -txt=myreport
sleep 10000
filereadline, lineout, C:\Program Files\CPUID\CPU-Z\myreport.txt, linenum
RegExMatch(lineout, ".. degC", regmat)
global regout := regexreplace(regmat,"( degC)", "")
return
readtemp2: ;this doesn't run CPU-Z and just reads the last value
filereadline, lineout, C:\Program Files\CPUID\CPU-Z\myreport.txt, linenum
RegExMatch(lineout, ".. degC", regmat)
global regout := regexreplace(regmat,"( degC)", "")
return
plfunc(){ ;xtucli
run %comspec% /k ""C:\Program Files (x86)\Intel\Intel(R) Extreme Tuning Utility\Client\xtucli.exe" -t -id 48 -v %pl1%",,hide
run %comspec% /k ""C:\Program Files (x86)\Intel\Intel(R) Extreme Tuning Utility\Client\xtucli.exe" -t -id 47 -v %pl2%",,hide
tooltip %pl1%`n%pl2%
sleep 1000
tooltip
return
}