ID Name Designator Footprint Quantity Manufacturer Part
"1" "0.1u" "C1,C2,C3,C5,C6,C7,C9,C13,C16" "C0805" "9" ""
"2" "220u" "C4" "CASE-D_7343" "1" ""
"3" "22u" "C8" "CASE-C_6032" "1" ""
"4" "1000u 25V" "C10,C11" "CAP-D12.5×F5.0" "2" ""
"5" "0.1u" "C12" "RAD-0.3" "1" ""
"6" "470u" "C14" "CASE-C_6032" "1" ""
"7" "220u" "C15" "CASE-C_6032" "1" ""
"8" "XH-5A_C26521" "CN1,CN2,CN4" "CONN-TH_5P-P2.50_XH-5A" "3" "XH-5A"
"9" "XH-8A_C722885" "CN5" "CONN-TH_XH-8A" "1" "XH-8A"
"10" "1SS352" "D1,D2" "SOD-323_L1.8-W1.3-LS2.5-RD" "2" "1SS355"
"11" "1N5817" "D3,D4" "D_DO-41_SOD81_P10.16MM_HORIZONTAL" "2" "1SS355"
"12" "KBU810" "D5" "KBU810" "1" "KBU810"
"13" "FUSE 1A" "F1" "FUSE_HOLDER_5X20MM_6A_250VAC" "1" ""
"14" "FUSE 5A" "F2" "FUSE_HOLDER_5X20MM_6A_250VAC" "1" ""
"15" "HDR-F-2.54_1x4" "H1" "HDR-F-2.54_1X4" "1" ""
"16" "M03JST-PTH" "JP1,JP2,JP3" "CONN-TH_3P-P2.50_CST_CS-1001-03K" "3" ""
"17" "G6S-2 DC12" "K1" "RELAY-TH_G6S-2" "1" "-"
"18" "RESET" "KEY1" "KEY-SMD_2P-L6.2-W3.6-LS8.0" "1" "K2-1107ST-A4SW-06"
"19" "FLASH" "KEY2" "KEY-SMD_2P-L6.2-W3.6-LS8.0" "1" "K2-1107ST-A4SW-06"
"20" "JST-2PIN" "N1,N2,N3,N4" "CONN-TH_2P-P2.50_CST_CS-1001-02K" "4" ""
"21" "CONN-TH_2P-P5.00" "P1,P2,P3" "CONN-TH_2P-P5.00" "3" ""
"22" "2SA1708S-AN" "Q1" "ONSC-NMP-3-135AD" "1" ""
"23" "KRC104S-RTK/P" "Q2" "SOT-23-3_L2.9-W1.6-P1.90-LS2.8-TR-CW" "1" "KRC104S-RTK/P"
"24" "DTU40N06" "Q3,Q5,Q6" "TO-252-2_L6.6-W6.1-P4.58-BR" "3" "DTU40N06"
"25" "BSS138W-F2-0000HF" "Q4" "SOT-323_L2.0-W1.3-P1.30-LS2.1-BR" "1" "BSS138W-F2-0000HF"
"26" "10k" "R1,R2,R3,R4,R5,R6,R13,R17" "R0805" "8" ""
"27" "2,2k" "R7" "R0805" "1" ""
"28" "1k" "R8,R9,R10" "R0805" "3" ""
"29" "22" "R11" "RES-TH_BD4.5-L11.5-P15.00-D0.6" "1" "MF1/2W-2K2±1%-2T52"
"30" "100k" "R12" "R0805" "1" ""
"31" "510" "R14,R18" "R0805" "2" "CRCW08053K90FKTA"
"32" "330" "R15,R19,R21,R23" "R0805" "4" "CRCW08053K90FKTA"
"33" "10K" "R16,R22,R24" "R0805" "3" "CRCW08053K90FKTA"
"34" "4,7k" "R20" "R0805" "1" ""
"35" "13K" "R25" "R0805" "1" ""
"36" "560" "R26" "R0805" "1" ""
"37" "120" "R27,R28" "R1206" "2" ""
"38" "JQX-105F-1/012D-1HS" "RELAY1" "RELAY-TH_JQX-105F-1-012D-1HS" "1" "JQX-105F-1/012D-1HS"
"39" "PTC10 TRANSFORMER" "T1" "PTC10 TRANSFORMER" "1" ""
"40" "PC817" "U1,U3,U4,U5" "PC817C SMD" "4" "FOD817A3SD"
"41" "ESP-32S-MY" "U2" "ESP32S" "1" ""
"42" "B1205S-1WSY" "U6,U9" "PWRM-TH_B1205S-1WSY" "2" "B1205S-1WSY"
"43" "L7812CV-DG" "U7" "TO-220-3_L10.0-W4.5-P2.54-L" "1" "L7812CV-DG"
"44" "LM1117-3,3" "U8" "SOT-223-3_L6.5-W3.4-P2.30-LS7.0-BR" "1" "LM317G-AA3-R"
"45" "23.5*16*25 Heat sink" "U10" "HEATSINK-TH_L23.5-W16.0-P18.0_XSD2156-067" "1" "23.5*16*25 2个钉散热片"