%SLX_LJTHERMISTOR Mask initialization for lj_ThermistorRead block
%
% slx_ljThermistor.m
% Julian Bell, JTEC Energy
% 2024-01-04
%
% This class definition configures & initializes the mask for the
% lj_ThermistorRead block in slx_LJM
%
% Relevant references:
% - XXX
%
% TODO:
% - Add control of other thermistor configuration parameters to mask
classdef slx_ljThermistor
properties
ljHandle double
ljID string
end
methods(Static)
% Following properties of 'maskInitContext' are available to use:
% - BlockHandle
% - MaskObject
% - MaskWorkspace: Use get/set APIs to work with mask workspace.
function MaskInitialization(maskInitContext)
% Create mask contexts
bh = maskInitContext.BlockHandle;
mo = maskInitContext.MaskObject;
mw = maskInitContext.MaskWorkspace;
% Get parent block ID
parentID = get_param(bh,'Parent');
try
disp('Trying to configure thermistor input')
% Get port & handle
ljPort = mw.get('ljPort');
ljPort = strip(ljPort,"'");
disp(['I think the port is...', num2str(ljPort)]);
% Get temp unit, thermistor resistance, and reference
% resistance
tempUnit = mw.get('tempUnit'); % For reasons I don't understand, this is formatted as {'C'}?
switch tempUnit
case 3
tempUnitIdx = 0;
case 1
tempUnitIdx = 1;
case 2
tempUnitIdx = 2;
otherwise
disp('Invalid temperature type - defaulting to C')
tempUnitIdx = 1;
end
disp(['The desired temperature output unit is ', num2str(tempUnit),' and the index is ', num2str(tempUnitIdx)]);
thermResVal= mw.get('thermRes');
disp(['The thermistor resistance value is ', num2str(thermResVal)]);
refResistanceVal = mw.get('refResistance');
disp(['The reference resistance value is ', num2str(refResistanceVal)]);
% Get handles
ljHandle = get_param(parentID,'ljHandle');
ljHandle = str2num(ljHandle);
disp(['I think the handle is...', num2str(ljHandle)]);
set_param(bh,'ljHandle',num2str(ljHandle));
mw.set('ljHandle',ljHandle);
% Run thermistor configuration script
ljThermistorConfigure(ljHandle,ljPort,false,50,tempUnitIdx,4,0,2.5,refResistanceVal,thermResVal,1.032e-3,2.387e-4,0,1.580e-7);
catch ljConnectErr
showErrorMessage(ljConnectErr);
disp(ljConnectErr)
LabJack.LJM.CloseAll();
end
end
% Use the code browser on the left to add the callbacks.
end
end