@Amin0G
Copy link

Amin0G commented Jan 17, 2019

In the case of multiple branches/transformers between two buses, CKT should uniquely identify such branches/transformers. However, the current version of the code is using "1" for CKT in all cases and this causes problems while using the RAW file.

@rdzman rdzman self-assigned this Jan 17, 2019
@rdzman rdzman added the bug label Jan 18, 2019
@rdzman
Copy link
Member

rdzman commented Jan 18, 2019

Thanks @Amin0G. Let me know if this fixes the issue for you.

@rdzman rdzman closed this as completed in 7841457 Jan 18, 2019