Skip to content
This repository has been archived by the owner on Mar 8, 2023. It is now read-only.

LMS511-20100 Pro Driver use questions #100

Closed
WangQJuan opened this issue Aug 26, 2020 · 4 comments
Closed

LMS511-20100 Pro Driver use questions #100

WangQJuan opened this issue Aug 26, 2020 · 4 comments

Comments

@WangQJuan
Copy link

5xx.launch
In the process of using, I want to configure the angular resolution and rotation speed of the laser. There was a problem.
At present, I can only use the default 35Hz

I'd like to ask you how to do it. Thank you

1.set


[ERROR] [1598438538.450053089]: Error Sopas answer mismatch Error unexpected Sopas Answer for request <Len=0036>sMN mLMPsetscancfg 0x2b 0x02 0x05 0x00 0x00 0x20 0x01 0x20 0x2b 0x01 0x06 0x06 0x07 0x20 0x00 0x20 0x00 CRC:<0x53>Answer= >>>sFA\x00\x08<<<

2.set


[ WARN] [1598438519.558494118]: Data length is outside acceptable range 1-381 (1141). Ignoring scan
[ WARN] [1598438519.597887486]: Data length is outside acceptable range 1-381 (1141). Ignoring scan
[ WARN] [1598438519.638020280]: Data length is outside acceptable range 1-381 (1141). Ignoring scan
[ WARN] [1598438519.677837551]: Data length is outside acceptable range 1-381 (1141). Ignoring scan

@michael1309
Copy link
Collaborator

What is your preferred setting for angular resolution and rotation speed?

@WangQJuan
Copy link
Author

I understand that angular resolution is relative to rotation speed I need a 0.1667 0.5 configuration. Of course, I want to be able to configure all the resolutions supported by the device

@chance2006
Copy link

Dear Micheal:
WangQJuan is our customer. He found that he must get an error if he change the frequency or angular resolution. They directly change 48&49 lines in our launch file
https://github.com/SICKAG/sick_scan/blob/master/launch/sick_lms_5xx.launch
The error
[ERROR] [1598438538.450053089]: Error Sopas answer mismatch Error unexpected Sopas Answer for request <Len=0036>sMN mLMPsetscancfg 0x2b 0x02 0x05 0x00 0x00 0x20 0x01 0x20 0x2b 0x01 0x06 0x06 0x07 0x20 0x00 0x20 0x00 CRC:<0x53>Answer= >>>sFA\x00\x08<<<
Woud you kindly check it? Thanks very much!

Best Regards!
Chester Hao

@michael1309
Copy link
Collaborator

Dear Chester,

Thanks for your feedback. We have fixed this inconsistency and checked in the new version 1.7.8.
Please check out this version in the master branch.
This should solve the customer's issue.

Best Regards,
Michael