You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
control sen5x debug 1
SEN5X PM 1.0: 1
Sensor not recognized, or no control interface available for this sensor
Culprit is the function sensorNameEndsIn, that doesn't work for more than two commands, and seems to return the wrong index for the command to be cleaned at.
IMPORTANT, when testing, it's important to check #60
The text was updated successfully, but these errors were encountered:
Control commands for sensors don't parse correctly when there are more than two words on the command:
This works:
Or:
But this doesn't:
Culprit is the function
sensorNameEndsIn
, that doesn't work for more than two commands, and seems to return the wrong index for the command to be cleaned at.IMPORTANT, when testing, it's important to check #60
The text was updated successfully, but these errors were encountered: