Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Erreur depuis passage en mode standard. #285

Open
blackmessor opened this issue Sep 27, 2024 · 11 comments
Open

Erreur depuis passage en mode standard. #285

blackmessor opened this issue Sep 27, 2024 · 11 comments

Comments

@blackmessor
Copy link

blackmessor commented Sep 27, 2024

Bonjour, j’ai 1Z Linky avec le Firmware 14 sous zigbee2mqtt. Mon abonnement électrique est tempo. Tout fonctionnait très bien lorsque mon compteur était en mode historique, mais depuis le passage en mode standard, je n’arrive plus à faire fonctionner le Z Linky, j’ai tenté un réapairage de zéro, mais au moment d’intégrer le réseau, cela fait même planter mon zigbee2mqtt qui n’arrive plus à se connecter au broker à cause de message mal formater

Pour faire face à cela. J’ai limité les données, renvoyer par le zlinky, et cela fonctionne mieux, pourtant, au bout de quelques minutes, à chaque fois, les données cessent de remonter, comme si le compteur était planté.
y a t’il une solution. ?

Merci d’avance.

Capture d’écran 2024-09-27 à 15 15 20
Capture d’écran 2024-09-27 à 15 15 38

@freeddoo
Copy link

Salut à tous je suis exactement dans le même cas pour les valeurs
Je suis en HP/HC mode standard et il reste constamment sur HC. Si je mets le tarif sur AUTO il me plante mon installation.

Merci de votre aide

@fairecasoimeme
Copy link
Owner

Pouvez-vous montrer les messages d'erreurs ou des logs ?

@freeddoo
Copy link

freeddoo commented Oct 1, 2024

Merci de ton aide si joint les seul info que j'ai:
{
"active_energy_out_d01": 0,
"active_energy_out_d02": 0,
"active_power": 0,
"active_power_max": 0,
"active_power_ph_b": 0,
"apparent_power": 1230,
"available_power": 45,
"average_rms_voltage_meas_period": 0,
"current_date": "",
"current_index_tarif": 0,
"current_price": "",
"current_summ_delivered": 0,
"current_summ_received": 0,
"current_tarif": "HC..",
"current_tier1_summ_delivered": 3888.432,
"current_tier2_summ_delivered": 3292.003,
"drawn_v_a_max_n1": 0,
"injected_active_load_n": 0,
"injected_active_load_n1": 0,
"injected_v_a": 0,
"injected_v_a_max_n": 0,
"injected_v_a_max_n1": 0,
"last_seen": "2024-10-01T18:19:51.030Z",
"linkquality": 185,
"message1": "",
"message2": "",
"meter_serial_number": "032361061720",
"reactive_power": 0,
"reactive_power_ph_b": 0,
"reactive_power_ph_c": 0,
"relais": 0,
"relais_breakout": {
"relais1": 0,
"relais2": 0,
"relais3": 0,
"relais4": 0,
"relais5": 0,
"relais6": 0,
"relais7": 0,
"relais8": 0
},
"rms_current": 7,
"rms_voltage": 0,
"site_id": "",
"status_register": "",
"status_register_breakout": {
"cache_borne_dist": "ferme",
"comm_euridis": "desactivee",
"contact_sec": "ferme",
"depassement_ref_pow": 0,
"etat_cpl": "nouveau_deverrouille",
"horloge": "correcte",
"organe_coupure": "ferme",
"pointe_mobile": "AUCUN",
"preavis_pointe_mobile": "AUCUN",
"producteur": 0,
"sens_energie_active": "positive",
"surtension_phase": 0,
"sync_cpl": "non_synchronise",
"tarif_dist": "index_1",
"tarif_four": "index_1",
"tempo_demain": "UNDEF",
"tempo_jour": "UNDEF",
"type_tic": "historique"
},
"total_reactive_power": 0,
"update": {
"installed_version": 14,
"latest_version": 14,
"state": "idle"
},
"update_available": false,
"warn_d_p_s": 0,
"power_threshold": null,
"software_revision": null
}

4z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky', payload '{"active_energy_out_d01":0,"active_energy_out_d02":0,"active_power":0,"active_power_max":0,"active_power_ph_b":0,"apparent_power":1210,"available_power":45,"average_rms_voltage_meas_period":0,"current_date":"","current_index_tarif":0,"current_price":"","current_summ_delivered":0,"current_summ_received":0,"current_tarif":"HC..","current_tier1_summ_delivered":3888.432,"current_tier2_summ_delivered":3292.017,"drawn_v_a_max_n1":0,"injected_active_load_n":0,"injected_active_load_n1":0,"injected_v_a":0,"injected_v_a_max_n":0,"injected_v_a_max_n1":0,"last_seen":"2024-10-01T18:21:04.315Z","linkquality":185,"message1":"","message2":"","meter_serial_number":"032361061720","power_threshold":null,"reactive_power":0,"reactive_power_ph_b":0,"reactive_power_ph_c":0,"relais":0,"relais_breakout":{"relais1":0,"relais2":0,"relais3":0,"relais4":0,"relais5":0,"relais6":0,"relais7":0,"relais8":0},"rms_current":5,"rms_voltage":0,"site_id":"","software_revision":null,"status_register":"","status_register_breakout":{"cache_borne_dist":"ferme","comm_euridis":"desactivee","contact_sec":"ferme","depassement_ref_pow":0,"etat_cpl":"nouveau_deverrouille","horloge":"correcte","organe_coupure":"ferme","pointe_mobile":"AUCUN","preavis_pointe_mobile":"AUCUN","producteur":0,"sens_energie_active":"positive","surtension_phase":0,"sync_cpl":"non_synchronise","tarif_dist":"index_1","tarif_four":"index_1","tempo_demain":"UNDEF","tempo_jour":"UNDEF","type_tic":"historique"},"total_reactive_power":0,"update":{"installed_version":14,"latest_version":14,"state":"idle"},"update_available":false,"warn_d_p_s":0}'

@fairecasoimeme
Copy link
Owner

Il semblerait que votre Linky soit en mode historique et non pas standard:

vous pouvez suivre le lien suivant pour faire la demande de passage en mode standard :

  • si vous êtes chez EDF, vous pouvez effectuer la demande à travers ce formulaire de votre espace en ligne, en choisissant ensuite "Modifier le statut de la Télé Information Client (TIC)" puis en précisant que vous souhaitez passer en mode standard dans le champ commentaire.
  • si vous n'êtes pas chez EDF, il faut appeler votre Fournisseur d'Electricité, et demander le passage de votre compteur Linky en mode standard, en précisant qu’il s’agit de la prestation F185 auprès d'Enedis.

Cette opération est gratuite et en général, le changement est effectué dans les 24 heures ouvrées.

@freeddoo
Copy link

freeddoo commented Oct 2, 2024

Merci de t'intéresser au problème.
Je suis bien en mode standard, confirmé par mon fournisseur d'électricité et j'ai également sur l'écran de mon linky STANDARD MODE TIC

@fairecasoimeme
Copy link
Owner

OK les logs des données montrent un mode historique en mode HCHP.

C'est quoi les messages mal formatés ? ya quoi dans l'onglet "Journaux" ?

@freeddoo
Copy link

freeddoo commented Oct 4, 2024

Ci-joint les logs
2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky', payload '{"active_energy_out_d01":0,"active_energy_out_d02":0,"active_power":0,"active_power_max":0,"active_power_ph_b":0,"apparent_power":2127,"available_power":45,"average_rms_voltage_meas_period":0,"current_date":"","current_index_tarif":0,"current_price":"","current_summ_delivered":0,"current_summ_received":0,"current_tarif":"HC..","current_tier1_summ_delivered":3933.638,"current_tier2_summ_delivered":3358.982,"drawn_v_a_max_n1":0,"injected_active_load_n":0,"injected_active_load_n1":0,"injected_v_a":0,"injected_v_a_max_n":0,"injected_v_a_max_n1":0,"last_seen":"2024-10-04T17:32:13.283Z","linkquality":189,"message1":"","message2":"","meter_serial_number":"032361061720","power_threshold":null,"reactive_power":0,"reactive_power_ph_b":0,"reactive_power_ph_c":0,"relais":0,"relais_breakout":{"relais1":0,"relais2":0,"relais3":0,"relais4":0,"relais5":0,"relais6":0,"relais7":0,"relais8":0},"rms_current":6,"rms_voltage":0,"site_id":"","software_revision":null,"status_register":"003A4501","status_register_breakout":{"cache_borne_dist":"ferme","comm_euridis":"activee avec securite","contact_sec":"ouvert","depassement_ref_pow":0,"etat_cpl":"nouveau_verrouille","horloge":"correcte","organe_coupure":"ferme","pointe_mobile":"AUCUN","preavis_pointe_mobile":"AUCUN","producteur":1,"sens_energie_active":"positive","surtension_phase":0,"sync_cpl":"non_synchronise","tarif_dist":"index_2","tarif_four":"index_2","tempo_demain":"UNDEF","tempo_jour":"UNDEF","type_tic":"standard"},"total_reactive_power":0,"update":{"installed_version":14,"latest_version":14,"state":"idle"},"update_available":false,"warn_d_p_s":0}'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/current_tarif', payload 'HC..'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/update-state', payload 'idle'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/update-installed_version', payload '14'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/update-latest_version', payload '14'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/update_available', payload 'false'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/rms_current', payload '6'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/apparent_power', payload '2127'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/current_tier1_summ_delivered', payload '3933.638'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/current_tier2_summ_delivered', payload '3358.982'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/last_seen', payload '2024-10-04T17:32:13.283Z'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/linkquality', payload '189'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/current_index_tarif', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/current_date', payload ''
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/active_energy_out_d01', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/active_energy_out_d02', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/current_price', payload ''
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/injected_active_load_n', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/injected_active_load_n1', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/injected_v_a', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/injected_v_a_max_n', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/injected_v_a_max_n1', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/message1', payload ''
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/drawn_v_a_max_n1', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/message2', payload ''
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-contact_sec', payload 'ouvert'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-organe_coupure', payload 'ferme'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-cache_borne_dist', payload 'ferme'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-surtension_phase', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-depassement_ref_pow', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-producteur', payload '1'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-sens_energie_active', payload 'positive'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-tarif_four', payload 'index_2'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-tarif_dist', payload 'index_2'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-horloge', payload 'correcte'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-type_tic', payload 'standard'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-comm_euridis', payload 'activee avec securite'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-etat_cpl', payload 'nouveau_verrouille'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-sync_cpl', payload 'non_synchronise'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-tempo_jour', payload 'UNDEF'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-tempo_demain', payload 'UNDEF'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-preavis_pointe_mobile', payload 'AUCUN'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register_breakout-pointe_mobile', payload 'AUCUN'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/status_register', payload '003A4501'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/relais_breakout-relais1', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/relais_breakout-relais2', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/relais_breakout-relais3', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/relais_breakout-relais4', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/relais_breakout-relais5', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/relais_breakout-relais6', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/relais_breakout-relais7', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/relais_breakout-relais8', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/relais', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/total_reactive_power', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/active_power', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/average_rms_voltage_meas_period', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/active_power_ph_b', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/rms_voltage', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/reactive_power', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/reactive_power_ph_b', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/reactive_power_ph_c', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/active_power_max', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/current_summ_delivered', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/current_summ_received', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/site_id', payload ''
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/meter_serial_number', payload '032361061720'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/available_power', payload '45'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/warn_d_p_s', payload '0'
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/power_threshold', payload ''
info 2024-10-04 19:32:13z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Linky/software_revision', payload ''

J'ai toujours HC alors que je devrais avoir HP la journée par exemple.
J'ai pas la tension qui remonte
image.

PS: Ne pas se fier au information affiche sur le linky. Même si le mode standard est affiche la fonction F185 n'est pas forcement fonctionnelle. Après un teste de ma clesur un autre compteur linky qui a également le mode standard j'ai toute les informations.
J'ai contacte hier mon fournisseur et il m'a confirme qu'il ne faut pas se fier à l'affichage et il me l'a activé.

Merci quand meme je vais pouvoir tester maintenant en plus approfondie.

@fairecasoimeme
Copy link
Owner

Bonjour,

Désolé mais l'information NGTF qui donne HC.. n'est pas possible. HC.. existe uniquement en mode historique.

(NGTF et OPTARIF ont le même cluster/attribut). Vous avez donc paramétrer votre Z2M en standard mais votre Linky est toujours en mode historique.

@chpego
Copy link

chpego commented Oct 14, 2024

Je suis dans le même cas (quasiment) :
Mon Linky était en mode historique, et tout était paramétré correctement dans Z2M (mode, phase, production)
Depuis le passage du mode historique à standard sur le Linky, la modification phase dans Z2M, fait planter Z2M qui n'arrive plus à se connecter au serveur MQTT.

Les logs:

  • Z2M:
    2024-10-14 06:07:36z2m: Cannot send message: topic: 'zigbee2mqttHA1/0x00158d0005be9f06', payload: '{"active_energy_out_d01":null,"active_energy_out_d02":null,"active_energy_out_d03":null,"active_energy_out_d04":null,"active_power":null,"active_power_max":null,"active_power_ph_b":null,"active_register_tier_delivered":"","apparent_power":429,"available_power":6,"average_rms_voltage_meas_period":null,"current_date":null,"current_index_tarif":null,"current_price":null,"current_summ_delivered":1698,"current_tarif":"Base","current_tier10_summ_delivered":null,"current_tier1_summ_delivered":1699,"current_tier2_summ_delivered":0,"current_tier3_summ_delivered":0,"current_tier4_summ_delivered":0,"current_tier5_summ_delivered":0,"current_tier6_summ_delivered":0,"current_tier7_summ_delivered":null,"current_tier8_summ_delivered":null,"current_tier9_summ_delivered":null,"days_number_current_calendar":null,"days_number_next_calendar":null,"days_profile_current_calendar":null,"days_profile_next_calendar":null,"drawn_v_a_max_n1":null,"linkquality":255,"message1":null,"message2":null,"meter_serial_number":"022261111942","mot_d_etat":"000000","power_threshold":null,"relais":null,"rms_current":2,"rms_current_max":0,"rms_voltage":null,"schedule_h_p_h_c":0,"site_id":null,"software_revision":null,"start_mobile_point1":null,"start_mobile_point2":null,"start_mobile_point3":null,"start_notice_e_j_p":0,"status_register":"003A0000","status_register_breakout":{"cache_borne_dist":"ferme","comm_euridis":"activee avec securite","contact_sec":"ferme","depassement_ref_pow":0,"etat_cpl":"nouveau_verrouille","horloge":"correcte","organe_coupure":"ferme","pointe_mobile":"AUCUN","preavis_pointe_mobile":"AUCUN","producteur":0,"sens_energie_active":"positive","surtension_phase":0,"sync_cpl":"non_synchronise","tarif_dist":"index_1","tarif_four":"index_1","tempo_demain":"UNDEF","tempo_jour":"UNDEF","type_tic":"standard"},"stop_mobile_point1":null,"stop_mobile_point2":null,"stop_mobile_point3":null,"tomorrow_color":"","update":{"installed_version":14,"latest_version":14,"state":"idle"},"update_available":false,"warn_d_p_s":0}
  • MQTT
    2024-10-14 06:07:50: Client mqttjs_9f999ecd disconnected due to malformed packet.

@fairecasoimeme
Copy link
Owner

Essayez de passer/forcer le "poll chunk" à 1

@chpego
Copy link

chpego commented Oct 22, 2024

Alors si jamais ça peut servir à d'autres; voilà ce que j'ai réalisé pour que cela fonctionne et sans plus aucune erreur lié à MQTT.
Appairage de la clé LiXee; une fois appairé il faut la déconnecter, faire les différents réglages dans Z2M (historique/standard, mono phase/tri phasé, poll chunk à 1, etc..); puis rebranché la clé LiXee

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

4 participants