You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
When I build SGXDataCenterAttestationPrimitives/SampleCode/QuoteVerificationSample and run app, I got a Warning with code a003 in the verification:
Trusted quote verification:
Info: get target info successfully returned.
Info: sgx_qv_set_enclave_load_policy successfully returned.
Info: tee_get_quote_supplemental_data_version_and_size successfully returned.
Info: latest supplemental data major version: 3, minor version: 3, size: 536
Info: App: tee_verify_quote successfully returned.
Info: Ecall: Verify QvE report and identity successfully returned.
Warning: App: Verification completed with Non-terminal result: a003
Info: Supplemental data Major Version: 3
Info: Supplemental data Minor Version: 3
===========================================
Untrusted quote verification:
Info: tee_get_quote_supplemental_data_version_and_size successfully returned.
Info: latest supplemental data major version: 3, minor version: 3, size: 536
Info: App: tee_verify_quote successfully returned.
Warning: App: Verification completed with Non-terminal result: a003
Info: Supplemental data Major Version: 3
Info: Supplemental data Minor Version: 3
I referred to /opt/intel/sgxsdk/include/sgx_qve_header.h for the code a003 and found:
SGX_QL_QV_RESULT_OUT_OF_DATE_CONFIG_NEEDED = SGX_QL_QV_MK_ERROR(0x0003),
///< The Quote is good but the TCB level of the platform is out
///< date and additional configuration of the SGX Platform at it
///< current patching level may be needed. The platform needs
///< patching to be at the latest TCB level
The experiment was done on Ubuntu 20.04 on a SGX server. I've updated SGX SDK, Intel PCCS and SGX SSL Library and got code a002. Then I updated BIOS and got code a003. This problem made me fail to finish remote attestation with librats. I wonder how can I fix it.
The text was updated successfully, but these errors were encountered:
When I build
SGXDataCenterAttestationPrimitives/SampleCode/QuoteVerificationSample
and run app, I got aWarning
with codea003
in the verification:I referred to
/opt/intel/sgxsdk/include/sgx_qve_header.h
for the codea003
and found:The experiment was done on Ubuntu 20.04 on a SGX server. I've updated SGX SDK, Intel PCCS and SGX SSL Library and got code
a002
. Then I updated BIOS and got codea003