Diagnostics data and alarms for optical transceivers (SFP, SFP+ or XFP).
Namespace: /intel/net/<driver name>/<device name>/dom/<metric name>
Metric Name | Description |
---|---|
alarm_warning_flags_implemented | Alarm warning flags implemented (yes/no). |
br_nominal | The nominal bit rate is specified in units of 100 Megabits per second. |
connector | The connector value indicates the external connector provided on the interface. A value 1 means SC, a value 7 means LC. |
encoding | The encoding value indicates the serial encoding mechanism. Values: 0 - Unspecified; 1 - 8B10B; 2 - 4B5B; 3 - NRZ; 4 - Manchester; 5 - SONET Scrambled; |
extended_identifier | This object describes the extended identifier value specifies the physical device described by the serial information. A value 4 means GBIC/SFP defined by 2-wire interface ID. |
identifier | This object describes the identifier value specifies the physical device described by the serial information. A value 3 means SFP. |
laser_bias_current | Displays the magnitude of the laser bias power current, in milliamperes (mA). The laser bias provides direct modulation of laser diodes and modulates currents. |
laser_bias_current_high_alarm | Displays whether the laser bias current high alarm is On or Off. |
laser_bias_current_high_alarm_threshold | Displays the vendor-specified threshold for the laser bias current high alarm. |
laser_bias_current_high_warning | Displays whether the laser bias current high warning is On or Off. |
laser_bias_current_high_warning_threshold | Displays the vendor-specified threshold for the laser bias current high warning. |
laser_bias_current_low_alarm | Displays whether the laser bias current low alarm is On or Off. |
laser_bias_current_low_alarm_threshold | Displays the vendor-specified threshold for the laser bias current low alarm. |
laser_bias_current_low_warning | Displays whether the laser bias current low warning is On or Off. |
laser_bias_current_low_warning_threshold | Displays the vendor-specified threshold for the laser bias current low warning. |
laser_output_power | Displays the laser output power, in milliwatts (mW) and decibels referred to 1.0 mW (dBm). |
laser_output_power_high_alarm | Displays whether the laser output power high alarm is On or Off. |
laser_output_power_high_alarm_threshold | Displays the vendor-specified threshold for the laser output power high alarm. |
laser_output_power_high_warning | Displays whether the laser output power high warning is On or Off. |
laser_output_power_high_warning_threshold | Displays the vendor-specified threshold for the laser output power high warning. |
laser_output_power_low_alarm | Displays whether the laser output power low alarm is On or Off. |
laser_output_power_low_alarm_threshold | Displays the vendor-specified threshold for the laser output power low alarm. |
laser_output_power_low_warning | Displays whether the laser output power low warning is On or Off. |
laser_output_power_low_warning_threshold | Displays the vendor-specified threshold for the laser output power low warning. |
laser_rx_power(2) | Displays the receive laser optical power, in milliwatts (mW) and decibels referred to 1.0 mW (dBm). |
laser_rx_power_high_alarm | Displays whether the receive laser power high alarm is On or Off. |
laser_rx_power_high_alarm_threshold | Displays the vendor-specified threshold for the receive laser power high alarm. |
laser_rx_power_high_warning | Displays whether the receive laser power high warning is On or Off. |
laser_rx_power_high_warning_threshold | Displays the vendor-specified threshold the receive laser power high warning. |
laser_rx_power_low_alarm | Displays whether the receive laser power low alarm is On or Off. |
laser_rx_power_low_alarm_threshold | Displays the vendor-specified threshold forthe receive laser power low alarm. |
laser_rx_power_low_warning | Displays whether the receive laser power low warning is On or Off. |
laser_rx_power_low_warning_threshold | Displays the vendor-specified threshold for the receive laser power low warning. |
laser_wavelength | The fibre channel transmitter wave laser length (nm). |
length_50um | This value specifies the link length that is supported while operating in compliance with the applicable standards using 50 micron multi-mode fiber. The value is in units of 10 meters. A value of 255 means that a link length greater than 2.54 km is supported. A value of zero means that the 50 micron multi-mode fiber is not supported or that the length information must be determined from the transceiver technology. |
length_62.5um | This value specifies the link length that is supported while operating in compliance with the applicable standards using 62.5 micron multi-mode fiber. The value is in units of 10 meters. A value of 255 means that a link length information must determined from the transceiver technology. It is common to support both 50 micron and 62.5 micron fiber. |
length_copper | This value specifies the minimum link length that is supported while operating in compliance with the applicable standards using copper cable. The value is in units of 1 meter. A value of 255 means that a link length greater than 254 meters is supported. A value of zero means that the copper cables are not supported or that the length information must be determined from the transceiver technology. |
length_om3 | This value specifies the minimum link length that is supported while operating in compliance with the applicable standards using OM3 multimode fibers. |
length_smf | This value specifies the minimum link length that is supported while operating in compliance with the applicable standards using single-mode (SFM) optical fibers. The value is in units of meters. A value of zero means that the SFM fibers are not supported or that the length information must be determined from the transceiver technology. |
length_smf_km | This value specifies the minimum link length that is supported while operating in compliance with the applicable standards using single-mode (SFM) optical fibers. The value is in units of kilometers. A value of zero means that the SFM fibers are not supported or that the length information must be determined from the transceiver technology. |
module_not_ready_alarm(2) | Displays whether the module not ready alarm is On or Off. |
module_power_down_alarm(2) | Displays whether the module power down alarm is On or Off. When the output is On, module is in a limited power mode, low for normal operation. |
module_temperature | Displays the temperature, in Celsius and Fahrenheit. |
module_temperature_high_alarm | Displays whether the module temperature high alarm is On or Off. |
module_temperature_high_alarm_threshold | Displays the vendor-specified threshold for the module temperature high alarm. |
module_temperature_high_warning | Displays whether the module temperature high warning is On or Off. |
module_temperature_high_warning_threshold | Displays the vendor-specified threshold for the module temperature high warning. |
module_temperature_low_alarm | Displays whether the module temperature low alarm is On or Off. |
module_temperature_low_alarm_threshold | Displays the vendor-specified threshold for the module temperature low alarm. |
module_temperature_low_warning | Displays whether the module temperature low warning is On or Off. |
module_temperature_low_warning_threshold | Displays the vendor-specified threshold for the module temperature low warning. |
module_voltage(1) | Displays the voltage in Volts. |
module_voltage_high_alarm(1) | Displays whether the module voltage high alarm is On or Off. |
module_voltage_high_alarm_threshold(1) | Displays the vendor-specified threshold for the module voltage high alarm. |
module_voltage_high_warning_threshold(1) | Displays the vendor-specified threshold for the module voltage high warning. |
module_voltage_low_alarm(1) | Displays whether the module voltage low alarm is On or Off. |
module_voltage_low_alarm_threshold(1) | Displays the vendor-specified threshold for the module voltage low alarm. |
module_voltage_low_warning(1) | Displays whether the module voltage low warning is On or Off. |
module_voltage_low_warning_threshold(1) | Displays the vendor-specified threshold for the module voltage low warning. |
optical_diagnostics_support | Displays whether the optical diagnostics is supported (yes/no). |
rate_identifier | |
receiver_signal_average_optical_power(1) | Displays the receiver signal average optical power, in milliwatts (mW) and decibels referred to 1.0 mW (dBm). |
rx_cdr_loss_of_lock_alarm(2) | Displays whether the Rx CDR (receive clock and data recovery) loss of lock alarm is On or Off. Triggered by loss of lock on the receive side of the CDR. |
rx_loss_of_signal(2) | Displays whether the Rx loss of signal alarm is On or Off. When on, indicates insufficient optical input power to the module. |
rx_not_ready_alarm(2) | Displays whether the Rx not ready alarm is On or Off. Triggered by any condition leading to invalid data on the receive path. |
transceiver_codes | This describes the transceiver compliance codes. |
transceiver_type | This describes the transceiver type information. |
tx_cdr_loss_of_lock_alarm(2) | Displays whether the Tx CDR (transmit clock and data recovery) loss of lock alarm is On or Off. Triggered by loss of lock on the transmit side of the CDR. |
tx_data_not_ready_alarm(2) | Displays whether the Tx data not ready alarm is On or Off. Triggered by any condition leading to invalid data on the transmit path. |
tx_laser_fault_alarm(2) | Displays whether the Tx laser fault alarm is On or Off. Triggered by laser fault condition. |
tx_not_ready_alarm(2) | Displays whether the Tx not ready alarm is On or Off. Triggered by any condition leading to invalid data on the transmit path. |
vendor_name | The vendor name contains the name of the corporation. |
vendor_oui | The vendor organizationally unique identifier field contains the IEEE Company Identifier for the vendor or zero if unspecified. |
vendor_pn | The vendor part number or product name, equals zero if unspecified. |
vendor_rev | The vendor revision number. |
Legend:
(1) Not available for XFP transceivers
(2) Not available for SFP and SFP+ transceivers
Notice:
Thresholds that trigger a high alarm, low alarm, high warning, or low warning are set by the transponder vendors. Generally, a high alarm or low alarm indicates that the optics module is not operating properly. This information can be used to diagnose why a transceiver is not working.