You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The capacity reserve margin does not account for hydrogen storage and electrolyzer power consumption (flexible load).
In the last update on the GenX policies for Capacity Reserve Margin, there was a term that accounted for asymmetric storage. This could be extended to account for hydrogen storage. However, this assumption needs to be validated.
Additionally, the complete power balancing equation (that includes conversion and storage of hydrogen and electrolyzer power consumption) needs to be reviewed to ensure that all flexible loads and storage resources are accounted for in the balancing equation.
The text was updated successfully, but these errors were encountered:
@Junwenlaw please push the changes you made to CRM constraint for the XOM project so that we can close this issue. Please make sure to modify the documentation along with the code changes to push this issue and any changes in input files.
The capacity reserve margin does not account for hydrogen storage and electrolyzer power consumption (flexible load).
In the last update on the GenX policies for Capacity Reserve Margin, there was a term that accounted for asymmetric storage. This could be extended to account for hydrogen storage. However, this assumption needs to be validated.
Additionally, the complete power balancing equation (that includes conversion and storage of hydrogen and electrolyzer power consumption) needs to be reviewed to ensure that all flexible loads and storage resources are accounted for in the balancing equation.
The text was updated successfully, but these errors were encountered: