Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathdsmr.sql
126 lines (108 loc) · 5.35 KB
/
dsmr.sql
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
/*
Date: 2013-08-01 14:10:46
*/
SET FOREIGN_KEY_CHECKS=0;
-- Create database
DROP DATABASE IF EXISTS dsmr;
CREATE DATABASE IF NOT EXISTS dsmr CHARACTER SET = utf8 COLLATE = utf8_general_ci;
USE dsmr;
-- ---------------------------
-- ----------------------------
-- Table structure for `energy`
-- ----------------------------
DROP TABLE IF EXISTS `energy`;
CREATE TABLE `energy` (
`ID` mediumint(8) unsigned NOT NULL AUTO_INCREMENT,
`Timestamp` timestamp NOT NULL DEFAULT CURRENT_TIMESTAMP,
`batchID` char(14) DEFAULT NULL COMMENT 'Batch ID',
`yy` smallint(4) unsigned NOT NULL DEFAULT '0' COMMENT 'Year',
`mm` smallint(2) unsigned NOT NULL DEFAULT '0' COMMENT 'Month',
`dd` smallint(2) unsigned NOT NULL DEFAULT '0' COMMENT 'Day',
`hh` smallint(2) unsigned NOT NULL DEFAULT '0' COMMENT 'Hour',
`min` smallint(2) unsigned NOT NULL DEFAULT '0' COMMENT 'Minute',
`sec` smallint(2) unsigned NOT NULL DEFAULT '0' COMMENT 'Second',
`ecl` decimal(9,4) unsigned NOT NULL DEFAULT '0.0000' COMMENT 'Electricity Consumption Tariff Low',
`ech` decimal(9,4) unsigned NOT NULL DEFAULT '0.0000' COMMENT 'Electricity Consumption Tariff High',
`edl` decimal(9,4) unsigned NOT NULL DEFAULT '0.0000' COMMENT 'Electricity Delivery Tariff Low',
`edh` decimal(9,4) unsigned NOT NULL DEFAULT '0.0000' COMMENT 'Electricity Delivery Tariff High',
`tc` tinyint(1) unsigned NOT NULL DEFAULT '0' COMMENT 'Tariff Code; 0=High, 1=Low',
`cec` decimal(9,4) unsigned NOT NULL DEFAULT '0.0000' COMMENT 'Current Electricity Consumption kWh',
`ced` decimal(9,4) unsigned NOT NULL DEFAULT '0.0000' COMMENT 'Current Electricity Delivery kWh',
`gc` decimal(9,4) unsigned NOT NULL DEFAULT '0.0000' COMMENT 'Gas Consumption',
`gr` datetime DEFAULT NULL COMMENT 'Last Gas Reading ',
`gt` tinyint(1) unsigned NOT NULL DEFAULT '0' COMMENT 'Gas throttle 0=Closed, 1=Open',
`type` varchar(255) DEFAULT NULL,
PRIMARY KEY (`ID`),
KEY `Timestamp` (`Timestamp`),
KEY `YY` (`yy`,`mm`,`dd`,`hh`,`min`,`sec`),
KEY `batchID` (`batchID`,`ID`)
) ENGINE=InnoDB DEFAULT CHARSET=utf8;
-- ----------------------------
-- Records of energy
-- ----------------------------
-- ----------------------------
-- Table structure for `portdata`
-- ----------------------------
DROP TABLE IF EXISTS `portdata`;
CREATE TABLE `portdata` (
`ID` mediumint(8) unsigned NOT NULL AUTO_INCREMENT,
`Timestamp` timestamp NOT NULL DEFAULT CURRENT_TIMESTAMP,
`batchID` char(14) DEFAULT NULL COMMENT 'batch id',
`portdata` varchar(255) DEFAULT NULL COMMENT 'raw data from port p1 of smartmeter',
PRIMARY KEY (`ID`),
KEY `Timestamp` (`Timestamp`),
KEY `batchID` (`batchID`)
) ENGINE=MEMORY DEFAULT CHARSET=utf8;
-- ----------------------------
-- Records of portdata
-- ----------------------------
-- ----------------------------
-- Procedure structure for `sp_portdata`
-- ----------------------------
DROP PROCEDURE IF EXISTS `sp_portdata`;
DELIMITER ;;
CREATE DEFINER=`root`@`10.%` PROCEDURE `sp_portdata`(IN `ibatchID` char(14))
BEGIN
declare rc int default 0;
declare cTimestamp datetime;
declare cID INT;
declare cbatchID,cportdata text;
declare raw CURSOR FOR select ID,`Timestamp`,batchID,portdata from portdata where batchID=ibatchID order by ID;
declare continue handler for not found set rc=1;
open raw;
set @f=0;
while rc=0 DO
fetch raw into cID,cTimestamp,cbatchID,cportdata;
set @yy = year(now());
set @mm = month(now());
set @dd = day(now());
set @hh = hour(now());
set @min = minute(now());
set @sec = second(now());
IF substr(cportdata,1,1)="/" then set @type = substr(cportdata,1);set @f=@f+1; # meter type
ELSEIF substr(cportdata,1,9)="1-0:1.8.1" then set @ecl = substr(cportdata,11,9);set @f=@f+1; # electric power consumption low
ELSEIF substr(cportdata,1,9)="1-0:1.8.2" then set @ech = substr(cportdata,11,9);set @f=@f+1; # electric power consumption high
ELSEIF substr(cportdata,1,9)="1-0:2.8.1" then set @edl = substr(cportdata,11,9);set @f=@f+1; # electric power delivery low
ELSEIF substr(cportdata,1,9)="1-0:2.8.2" then set @edh = substr(cportdata,11,9);set @f=@f+1; # electric power delivery high
ELSEIF substr(cportdata,1,11)="0-0:96.14.0" then set @tc = substr(cportdata,13,4);set @f=@f+1; # tarieffcode - 0=hoog;1=laag
ELSEIF substr(cportdata,1,9)="1-0:1.7.0" then set @cec = substr(cportdata,11,7);set @f=@f+1; # current electric power consumption
ELSEIF substr(cportdata,1,9)="1-0:2.7.0" then set @ced = substr(cportdata,11,7);set @f=@f+1; # current electric power delivery
ELSEIF substr(cportdata,1,10)="0-1:24.3.0" then set @gr = substr(cportdata,12,12);set @f=@f+1; # timestamp reading last gas consumption
ELSEIF substr(cportdata,1,1)="(" and substr(cportdata,11,1)=")" then set @gc=substr(cportdata,2,9);set @f=@f+1; # gas consumption in m3
ELSEIF substr(cportdata,1,10)="0-1:24.4.0" then set @gt = substr(cportdata,12,1);set @f=@f+1; # gas throttle - 0=closed, 1=open
else set @a=0;
end if;
end while;
if @f=11 THEN
start transaction;
# insert data into energy table
insert ignore into energy
(batchID,yy,mm,dd,hh,`min`,`sec`, ecl,ech,edl,edh,tc,cec,ced,gc,gr,gt,type)
values(ibatchID,@yy,@mm,@dd,@hh,@min,@sec,@ecl,@ech,@edl,@edh,@tc,@cec,@ced,@gc,@gr,@gt,@type);
# truncate (empty) portdata table
truncate portdata;
commit;
end if;
END
;;