Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathspaCodes.js
115 lines (104 loc) · 5.29 KB
/
spaCodes.js
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
//
// Set up message translation matrix (codes must be unique as they are used to store data in spa{})
//
// Note : xx to be replaced by channel number in main code
module.exports = {
"ff af 13" : { // Status update
"description" : "Status udpate",
//no ozone 17 03 67 0c 06 00 28 00 00 04 0c 00 00 02 00 00 00 00 02 06 64 00 00 00 1e 00 00
// 00 03 67 0c 07 00 28 00 00 04 0c 00 00 02 00 00 00 00 02 02 62 00 00 00 1e 00 00
//after wipe 17 03 67 0c 0e 00 28 00 00 04 0c 00 00 02 00 00 00 00 02 06 62 00 00 00 1e 00 00
//ff af 13 14 00 67 11 0e 00 00 67 67 04 0c 00 00 02 00 00 00 00 00 04 62 01 00 00 1e 00 00
//17 00 62 15 06 00 00 00 00 08 0c 00 00 02 00 00 00 00 00 04 60 00 00 00 1e 00 00
"codeLine" : "GF PF CT HH MM HM 00 TA TB FC HF PP 00 CP LF 00 00 00 00 CF ST TC 00 00 H2 00 00".split(" "),
"codes" : {
"GF" : "General flag (05 = on hold)", // set to 17 without A/B temperature sensor activated, set to 14 otherwise???
"PF" : "Priming flag (on start, goes through different stages: 04,42,05,01,00 ---0x01 = Priming)",
"CT" : "Current temperature (in F) -- 00 means no temp reading", // verified
"HH" : "Hours", // verified
"MM" : "Minutes", // verified
"HM" : "Heating mode (0x00 = Ready, 0x01 = Rest, 0x03?? = Ready in rest))", // verified for 0 and 1
"TA" : "Temp sensor A (inlet) (show hold remaining time if on hold : goes to 3c (60 min) first, then drops by 1 every minute)", // verified
"TB" : "Temp sensor B (outlet)", // verified
"FC" : "Filter cycle (04(low)/06(high) = cycle 1, 08(high) = cycle 2, ?? = both?? FC goes to 00 briefly when switching?)", // verified
"HF" : "Heat flag (0x04 = on hold in temp range high, 0x0c = not heating (high), 0x2c = waiting (high), 0x1c = heating (high), subtract 4 from all values for low range)", // verified
"PP" : "Pump status (0x02 for pump 1, 0x08 for pump 2, 0x0a for both -- added together)", // verified
"CP" : "Circ pump (0x00 = off, 0x02 = on)", // verified
"LF" : "Light flag (0x03 for on)", // verified
"CF" : "Cleanup cycle flag (0x04 off, 0x0c for on)",
"ST" : "Set temperature", // verified
"TC" : "Temperature A/B flag (0x00 = off, 0x01 = on)", // verified
"H2" : "Heat mode 2nd flag (0x00 = when HM is 01, 0x1e = when HM is 00, also goes to 00 if M8 set to off and goes back to 1e if M8 set to on)" // could be timer on m8?
}
},
"xx bf 23" : { // Filter configuration
"description" : "Filter configuration",
"codeLine" : "1H 1M 1D 1E 2H 2M 2D 2E".split(" "),
"codes" : {
"1H" : "Filter 1 start hour (always 0-24)",
"1M" : "Filter 1 start minute",
"1D" : "Filter 1 duration hours",
"1E" : "Filter 2 duration minutes",
"2H" : "Filter 2 start hour, masking out the high order bit, which is used as an enable/disable flag (mod 128)",
"2M" : "Filter 2 start minute",
"2D" : "Filter 2 duration hours",
"2E" : "Filter 2 duration minutes"
}
},
"xx bf 24" : { // Control configuration 1 ***seems same as ff af 26***!!!!!!!
"description" : "Control configuration 1",
// 64 c9 2c 00 4d 42 50 35 30 31 55 58 03 a8 2f 63 83 01 06 05 00
"codeLine" : "00 00 00 00 B1 B2 B3 B4 B5 B6 B7 B8 00 00 00 00 00 00 00 00 00".split(" "),
"codes" : {
"B1 to B8" : "Motherboard model in ASCII"
}
},
"xx bf 25" : { // Control configuration 2
"description" : "Control configuration 2",
// 09 03 32 63 50 68 49 03 41 02
"codeLine" : "00 00 00 00 00 00 00 00 00 00".split(" "),
"codes" : {
}
},
"xx bf 26" : { // Control configuration 3
"description" : "Control configuration 3",
// 00 87 00 01 00 01 00 00 01 00 00 00 00 00 00 00 00 00
"codeLine" : "00 00 RM TS TF CC 00 00 M8 00 00 00 00 00 00 00 00 00".split(" "),
"codes" : {
"RM" : "Reminders (0 = on, 1 = off)",
"TS" : "Temperature scale (0 = Fahrenheit, 1 = Celsius)",
"M8" : "M8 artificial intelligence (0 = off, 1 = on)",
"TF" : "Time format flag (0 = 12h, 1 = 24h)",
"CC" : "Cleaning cycle length (0 to 8, each integer is 0.5h increments)"
}
},
"xx bf 2e" : { // Control configuration 4
"description" : "Control configuration 4",
// 05 00 01 90 00 00
},
"xx bf 28" : { // Faults log
"description" : "Faults log",
// 0c 0a 10 55 17 21 10 64 60 66
"codeLine" : "TO EN EC ND FH FM FE FS FA FB".split(" "),
"codes" : {
"TO" : "Total number of entries", // verified
"EN" : "Entry number (add one to hex number)", // verified
"EC" : "Error code (see Spa Touch manual for list)", // verified
"ND" : "Number of days ago", // verified
"FH" : "Time (hour) of fault", // verified
"FM" : "Time (minute) of fault", // verified
"FE" : "Heat mode (01 = ready)", // verified
"FS" : "Set temp", // verified
"FA" : "Temp A", // verified
"FB" : "Temp B" // verified
}
},
"xx bf 2b" : { // GFCI test result
"description" : "GFCI test result",
// 01
"codeLine" : "GF".split(" "),
"codes" : {
"GF" : "GFCI test result (0 = not passed, 1 = passed)", // verified
}
}
}