# set_bias.py Converts desired bias voltage to DAC values and sends it to appropriate AFE
#Uses the new SPI slave firmware. Python 3.
import DaphneInterface as ivtools
import argparse
import numpy as np
from tqdm import tqdm
def main(ep,afe,ch,run_type):
afe = int(afe)
ch = int(ch)
device = ivtools.daphne(f"10.73.137.{ep}")
def DAC_for_V(afe, v):
if afe==0:
return abs(round((v-0.053)/0.0394))
elif afe==1:
return abs(round((v-0.0447)/0.0391))
elif afe==2:
return abs(round((v-0.00945)/0.0392))
elif afe==3:
return abs(round((v+0.371)/0.0391))
elif afe==4:
return abs(round((v-0.00328)/0.0391))
else:
raise ValueError("We only have AFE's 0-4!")
if run_type == 'warm':
vlimit = 53
vrange=[50.5,53]
elif run_type == 'cold':
vlimit = 47
vrange=[40, 47]
else:
raise Exception('run_type not recognized. warm or cold are only options')
print('WR VBIASCTRL V 4095')
response_data = device.command('WR VBIASCTRL V 4095')
viter = 0.05
v_list = np.arange(vrange[0], vrange[1], viter)
current = []
for v in v_list:
print(f'v = {v}')
if v==0:
dac = 0
elif v > vlimit:
raise Exception(f'Cannot set bias higher than {vlimit}')
else:
dac = DAC_for_V(afe, v)
CmdString = f"WR AFE {afe} BIASSET V {dac}"
device.command(CmdString)
I = device.read_current(8*afe+ch, 15)
current.append(I)
print(f'current = {I}')
#print(device.command('RD VM ALL'))
#print(device.read_current(0))
#print(device.read_current(1))
#print(device.read_current(2))
#print(device.read_current(3))
#print(device.read_current(4))
#print(device.read_current(5))
#print(device.read_current(6))
#print(device.read_current(7))
np.savez('iv_current_cold.npz', current=current, v=v_list)
device.close()
if __name__ == "__main__":
parser = argparse.ArgumentParser(description='DAPHNE command interpreter')
parser.add_argument('--ep', required=True, help='DAPHNE IP endpoint, e.g. 110')
parser.add_argument('--afe', required=True, help='Which AFE are we setting bias for? Number 0-4')
parser.add_argument('--ch', required=True, help='Which channel to check current? Number 0-7')
parser.add_argument('--run_type', required=True, help='Run type. Choose warm for warm test and cold for cold test.')
args = parser.parse_args()
main(args.ep,args.afe,args.ch, args.run_type)