Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Cutoff radius larger than half box length allowed in GCMC #98

Closed
GarrettLong opened this issue Jun 27, 2018 · 1 comment
Closed

Cutoff radius larger than half box length allowed in GCMC #98

GarrettLong opened this issue Jun 27, 2018 · 1 comment
Assignees

Comments

@GarrettLong
Copy link

GarrettLong commented Jun 27, 2018

While testing GCMC, simulations were allowed to proceed with a cutoff radius of 10 angstroms while the simulation (BOX0) box length was anywhere from 10 to 18 angstroms, with no warning printed or error thrown. The reservoir box length was 20 angstroms, which may have had something to do with it.

Example input files are on the TransitionMatrix branch in the /Confirmation_Results/Water_SPCE/Water_Inputs directory, as well as attached below.
Water_Inputs.zip

@msoroush
Copy link
Collaborator

msoroush commented Mar 4, 2019

Error checking is implemented in GOMC 2.40

@msoroush msoroush closed this as completed Mar 4, 2019
@YounesN YounesN mentioned this issue Jan 21, 2020
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment