Background: According to investigation by @Grogyan at #3548 the SPI speed is just a little too fast to read the MAX31855 thermocouple reliably. This might also apply to the MAX6675, but we haven't had any reports to that effect. So this PR supplies a patch for the MAX31855 only.
Solution: For the MAX31855 the SPI clock divider is set to 64. The MAX6675 still uses an SPI clock divider of 16.