Merge pull request #10747 from NREL/fixTransitionDupVRFTU
Browse files Browse the repository at this point in the history
Fix transition duplicate TU and fix End-Use Subcategory value
  • Loading branch information
Myoldmopar authored Sep 19, 2024
2 parents 6cff6e8 + 1756c4d commit cdf84cc
Showing 1 changed file with 5 additions and 3 deletions.
8 changes: 5 additions & 3 deletions src/Transition/CreateNewIDFUsingRulesV24_2_0.f90
Original file line number Diff line number Diff line change
Expand Up @@ -394,8 +394,10 @@ SUBROUTINE CreateNewIDFUsingRules(EndOfFile,DiffOnly,InLfn,AskForInput,InputFile
OldFanVO(NumOldFanVO)%coeff5 = TRIM(IDFRecords(Num)%Numbers(12)) !- Coefficient5 x**4
OldFanVO(NumOldFanVO)%inletAirNodeName = TRIM(IDFRecords(Num)%Alphas(4))
OldFanVO(NumOldFanVO)%outletAirNodeName = TRIM(IDFRecords(Num)%Alphas(5))
IF (lEN(IDFRecords(Num)%Alphas) .eq. 6) THEN
IF (SIZE(IDFRecords(Num)%Alphas) .eq. 6) THEN
OldFanVO(NumOldFanVO)%endUseSubCat = TRIM(IDFRecords(Num)%Alphas(6))
ELSE
OldFanVO(NumOldFanVO)%endUseSubCat = ''
ENDIF
IF (FindItemInList(TRIM(IDFRecords(Num)%Alphas(1)), vavFanNameToDelete, NumVRFTU) /= 0) THEN
DeleteThisRecord(Num) = .TRUE.
Expand Down Expand Up @@ -583,9 +585,9 @@ SUBROUTINE CreateNewIDFUsingRules(EndOfFile,DiffOnly,InLfn,AskForInput,InputFile
CASE('ZONEHVAC:TERMINALUNIT:VARIABLEREFRIGERANTFLOW')
isVariableVolume = .FALSE.
CALL GetNewObjectDefInIDD(ObjectName, NwNumArgs, NwAorN, NwReqFld, NwObjMinFlds, NwFldNames, NwFldDefaults, NwFldUnits)
nodiff = .false.
OutArgs(1:13) = InArgs(1:13)
IF (SameString(InArgs(14), 'FAN:VARIABLEVOLUME')) THEN
nodiff = .false.
isVariableVolume = .TRUE.
OutArgs(14) = 'Fan:SystemModel'
OutArgs(15) = TRIM(InArgs(15))
Expand All @@ -594,9 +596,9 @@ SUBROUTINE CreateNewIDFUsingRules(EndOfFile,DiffOnly,InLfn,AskForInput,InputFile
OutArgs(14:15) = InArgs(14:15)
ENDIF
OutArgs(16:CurArgs) = InArgs(16:CurArgs)
CALL WriteOutIDFLines(DifLfn, 'ZoneHVAC:TerminalUnit:VariableRefrigerantFlow', CurArgs, OutArgs, NwFldNames, NwFldUnits)

IF (isVariableVolume) THEN
CALL WriteOutIDFLines(DifLfn, 'ZoneHVAC:TerminalUnit:VariableRefrigerantFlow', CurArgs, OutArgs, NwFldNames, NwFldUnits)
! create fan system model object
ObjectName = 'Fan:SystemModel'
DO Num3 = 1, NumFanVariableVolume
Expand Down