Notifications
You must be signed in to change notification settings - Fork 425
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Merge remote-tracking branch 'remotes/origin/develop' into Beyond1Air…
…loop
- Loading branch information
Showing
216 changed files
with
163,078 additions
and
7,371 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
124 changes: 124 additions & 0 deletions
124
design/FY2016/AdaptiveComfortThermostat/AdaptiveComfortThermostat.md
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,124 @@ | ||
Thermostat Based-on Adaptive Thermal Comfort Models | ||
================ | ||
|
||
**Tianzhen Hong.** | ||
**Lawrence Berkeley National Laboratory** | ||
|
||
- Original Date: July 20, 2016 | ||
- Revised Date: July 29, 2016; October 21, 2016 | ||
|
||
## Justification for New Feature ## | ||
|
||
ASHRAE Standard 55-2010 and CEN 15251-2007 provide adaptive thermal comfort models for naturally ventilated buildings. The adaptive comfort models are getting used for mechanically cooled and ventilated buildings especially in hot climates to save energy. Users requested this feature. | ||
|
||
## Introduction ## | ||
|
||
ASHRAE Standard 55-2010, Thermal Environmental Conditions for Human Occupancy, introduces an adaptive thermal comfort model for spaces relying on occupants opening windows for natural ventilation and cooling. The adaptive comfort model relates the zone operative temperature setpoint to the outdoor air temperature, as a function defined in Figure 1. The adaptive comfort model only applies to cooling mode. | ||
|
||
 | ||
Figure 1. Acceptable operative temperature ranges based on the adaptive thermal comfort model of ASHRAE Standard 55-2010 | ||
|
||
The European standard CEN 15251-2007 has a similar adaptive comfort model as shown in Figure 2. | ||
|
||
 | ||
Figure 2. Acceptable operative temperature ranges based on CEN15251-2007 | ||
|
||
Basically during summer time in hot climates, the zone thermostat setting can be higher than the traditional thermostat setting based on the Fanger comfort theory, which results in energy savings of HVAC systems. The adaptive comfort model was originally developed for naturally ventilated buildings, but is now recommended for use with mechanically cooled and ventilated buildings, which may go into effect in future editions of ASHRAE Standard 55. | ||
This NFP will implement a new zone thermostat based on the adaptive comfort models in ASHRAE Standard 55-2010 as well as CEN 15251-2007. | ||
|
||
|
||
## E-mail and Conference Call Conclusions ## | ||
|
||
N/A | ||
|
||
## Overview ## | ||
|
||
The adaptive comfort model has been adopted in EnergyPlus as one of the thermal comfort models of the People object, as well as one control strategy to operate windows in the Airflow Network model. The existing code will be reused as much as possible. We propose to enhance the existing ZoneControl:Thermostat:OperativeTemperature object to indicate the applicability of the adaptive comfort model with seven choices: | ||
- **None**. The adaptive comfort model is not applicable; | ||
- **AdaptiveASH55_CentralLine**. The central line of the acceptability limits of the ASHRAE Standard 55-2010 adaptive comfort model will be used as the zone operative temperature setpoint; | ||
- **AdaptiveASH55_80PercentUpperLine**. The upper line of the 80% acceptability limits of the ASHRAE Standard 55-2010 adaptive comfort model will be used as the zone operative temperature setpoint; | ||
- **AdaptiveASH55_90PercentUpperLine**. The upper line of the 90% acceptability limits of the ASHRAE Standard 55-2010 adaptive comfort model will be used as the zone operative temperature setpoint; | ||
- **AdaptiveCEN15251_CentralLine**. The central line of the acceptability limits of the CEN Standard 15251-2007 adaptive comfort model will be used as the zone operative temperature setpoint; | ||
- **AdaptiveCEN15251_CategoryIUpperLine**. The upper line of the Category I of the acceptability limits of the CEN Standard 15251-2007 adaptive comfort model will be used as the zone operative temperature setpoint; | ||
- **AdaptiveCEN15251_CategoryIIUpperLine**. The upper line of the Category II of the acceptability limits of the CEN Standard 15251-2007 adaptive comfort model will be used as the zone operative temperature setpoint; and | ||
- **AdaptiveCEN15251_CategoryIIIUpperLine**. The upper line of the Category III of the acceptability limits of the CEN Standard 15251-2007 adaptive comfort model will be used as the zone operative temperature setpoint; | ||
|
||
When the adaptive comfort model is selected, the thermostat setpoint temperature schedule for space cooling will be overwritten with the calculated operative temperature based on the selected acceptability limits of the comfort model defined in ASHRAE 55-2010 or CEN 15251-2007. Such calculations have been implemented in EnergyPlus already. The ASHRAE adaptive comfort model is only applicable when the running average outdoor air temperature for the past 30 days is between 10.0 and 33.5°C; while the CEN 15251-2007 adaptive comfort model is only applicable when the running average outdoor air temperature for the past 7 days is between 10.0 and 30.0°C. | ||
|
||
|
||
## IDD Object (New) ## | ||
|
||
N/A | ||
|
||
## IDD Object(s) (Revised) ## | ||
|
||
As the adaptive comfort models are based on space operative temperature, we propose to modify the ZoneControl:Thermostat:OperativeTemperature object by adding a field to indicate which adaptive comfort model to use. If an adaptive comfort model is chosen, the thermostat setpoint schedule of the ThermostatSetpoint object, referenced by the ZoneControl:Thermostat object, will be overwritten accordingly. | ||
|
||
<pre> | ||
ZoneControl:Thermostat:OperativeTemperature, | ||
\memo This object can be used with the ZoneList option on a thermostat or with one | ||
\memo of the zones on that list (but you won't be able to use the object list to | ||
\memo pick only one of those zones. Thermostat names are <Zone Name> <global Thermostat name> internally. | ||
A1, \field Thermostat Name | ||
\note Enter the name of a ZoneControl:Thermostat object. | ||
\note This object modifies a ZoneControl:Thermostat object to add a | ||
\note radiative fraction. | ||
\required-field | ||
\type object-list | ||
\object-list ZoneControlThermostaticNames | ||
A2, \field Radiative Fraction Input Mode | ||
\required-field | ||
\type choice | ||
\key Constant | ||
\key Scheduled | ||
N1, \field Fixed Radiative Fraction | ||
\minimum 0.0 | ||
\maximum< 0.9 | ||
A3, \field Radiative Fraction Schedule Name | ||
\note Schedule values of 0.0 indicate no operative temperature control | ||
\type object-list | ||
\object-list ScheduleNames | ||
<b>A4</b> ; \field Adaptive Comfort Model Type | ||
\type choice | ||
\key None | ||
\key AdaptiveASH55_CentralLine | ||
\key AdaptiveASH55_80PercentUpperLine | ||
\key AdaptiveASH55_90PercentUpperLine | ||
\key AdaptiveCEN15251_CentralLine | ||
\key AdaptiveCEN15251_CategoryIUpperLine | ||
\key AdaptiveCEN15251_CategoryIIUpperLine | ||
\key AdaptiveCEN15251_CategoryIIIUpperLine | ||
\default None | ||
\note the cooling setpoint temperature schedule of the referenced thermostat will be adjusted based on the selected adaptive comfort model type | ||
|
||
</pre> | ||
|
||
## IO Ref ## | ||
To be developed. | ||
|
||
## EngRef ## | ||
The Engineering Reference already described the adaptive comfort models for ASHRAE Standard 55-2010 and CEN 15251-2007. | ||
|
||
## Example File and Transition Changes ## | ||
|
||
A new example will be created using the simple DOE small office reference model to demonstrate the new feature. | ||
|
||
## Proposed Report Variables ## | ||
None | ||
|
||
## Proposed additions to Meters ## | ||
None | ||
|
||
## Transition changes ## | ||
N/A | ||
|
||
## Other documents ## | ||
N/A | ||
|
||
## Reference ## | ||
|
||
ASHRAE Standard 55-2010. Thermal environment conditions for human occupancy. ASHRAE, Atlanta. | ||
|
||
EN 15251 (2007) Indoor environmental input parameters for design and assessment of energy performance of buildings- addressing indoor air quality, thermal environment, lighting and acoustics. CEN, Brussels. | ||
|
||
|
Binary file added
BIN
+171 KB
design/FY2016/AdaptiveComfortThermostat/AdaptiveComfortThermostat_ASHRAE55.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Binary file added
BIN
+435 KB
design/FY2016/AdaptiveComfortThermostat/AdaptiveComfortThermostat_CEN15251.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Oops, something went wrong.
f5ac122
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Beyond1Airloop (mjwitte) - x86_64-MacOS-10.9-clang: Tests Failed (2047 of 2400 tests passed, 250 test warnings)
f5ac122
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Beyond1Airloop (mjwitte) - x86_64-Linux-Ubuntu-14.04-gcc-4.8: Tests Failed (2087 of 2440 tests passed, 254 test warnings)
f5ac122
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Beyond1Airloop (mjwitte) - x86_64-Linux-Ubuntu-14.04-cppcheck-1.61: OK (0 of 0 tests passed, 0 test warnings)
f5ac122
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Beyond1Airloop (mjwitte) - x86_64-Linux-Ubuntu-14.04-gcc-4.8-UnitTestsCoverage-Debug: OK (1212 of 1232 tests passed, 0 test warnings)
f5ac122
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Beyond1Airloop (mjwitte) - x86_64-Linux-Ubuntu-14.04-gcc-4.8-IntegrationCoverage-Debug: OK (1795 of 1820 tests passed, 0 test warnings)
f5ac122
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Beyond1Airloop (mjwitte) - x86_64-Linux-Ubuntu-14.04-custom_check: Build Failed