Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[Improve][Docs] Refactor IoTDB sink docs #5306

Merged
merged 3 commits into from
Aug 23, 2023
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
151 changes: 54 additions & 97 deletions docs/en/connector-v2/sink/IoTDB.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,116 +2,73 @@

> IoTDB sink connector

## Description

Used to write data to IoTDB.

:::tip

There is a conflict of thrift version between IoTDB and Spark.Therefore, you need to execute `rm -f $SPARK_HOME/jars/libthrift*` and `cp $IOTDB_HOME/lib/libthrift* $SPARK_HOME/jars/` to resolve it.
## Support Those Engines

:::
> Spark<br/>
> Flink<br/>
> SeaTunnel Zeta<br/>

## Key features
## Key Features

- [x] [exactly-once](../../concept/connector-v2-features.md)

IoTDB supports the `exactly-once` feature through idempotent writing. If two pieces of data have
the same `key` and `timestamp`, the new data will overwrite the old one.

## Options

| name | type | required | default value |
|-----------------------------|---------|----------|--------------------------------|
| node_urls | list | yes | - |
| username | string | yes | - |
| password | string | yes | - |
| key_device | string | yes | - |
| key_timestamp | string | no | processing time |
| key_measurement_fields | array | no | exclude `device` & `timestamp` |
| storage_group | string | no | - |
| batch_size | int | no | 1024 |
| max_retries | int | no | - |
| retry_backoff_multiplier_ms | int | no | - |
| max_retry_backoff_ms | int | no | - |
| default_thrift_buffer_size | int | no | - |
| max_thrift_frame_size | int | no | - |
| zone_id | string | no | - |
| enable_rpc_compression | boolean | no | - |
| connection_timeout_in_ms | int | no | - |
| common-options | | no | - |

### node_urls [list]

`IoTDB` cluster address, the format is `["host:port", ...]`

### username [string]

`IoTDB` user username

### password [string]

`IoTDB` user password

### key_device [string]

Specify field name of the `IoTDB` deviceId in SeaTunnelRow

### key_timestamp [string]

Specify field-name of the `IoTDB` timestamp in SeaTunnelRow. If not specified, use processing-time as timestamp

### key_measurement_fields [array]

Specify field-name of the `IoTDB` measurement list in SeaTunnelRow. If not specified, include all fields but exclude `device` & `timestamp`

### storage_group [string]

Specify device storage group(path prefix)

example: deviceId = ${storage_group} + "." + ${key_device}

### batch_size [int]

For batch writing, when the number of buffers reaches the number of `batch_size` or the time reaches `checkpoint.interval`, the data will be flushed into the IoTDB

### max_retries [int]

The number of retries to flush failed

### retry_backoff_multiplier_ms [int]

Using as a multiplier for generating the next delay for backoff

### max_retry_backoff_ms [int]

The amount of time to wait before attempting to retry a request to `IoTDB`

### default_thrift_buffer_size [int]

Thrift init buffer size in `IoTDB` client

### max_thrift_frame_size [int]

Thrift max frame size in `IoTDB` client

### zone_id [string]

java.time.ZoneId in `IoTDB` client

### enable_rpc_compression [boolean]

Enable rpc compression in `IoTDB` client
## Description

### connection_timeout_in_ms [int]
Used to write data to IoTDB.

The maximum time (in ms) to wait when connecting to `IoTDB`
:::tip

### common options
There is a conflict of thrift version between IoTDB and Spark.Therefore, you need to execute `rm -f $SPARK_HOME/jars/libthrift*` and `cp $IOTDB_HOME/lib/libthrift* $SPARK_HOME/jars/` to resolve it.

Sink plugin common parameters, please refer to [Sink Common Options](common-options.md) for details
:::

## Examples
## Supported DataSource Info

| Datasource | Supported Versions | Url |
|------------|--------------------|----------------|
| IoTDB | `>= 0.13.0` | localhost:6667 |

## Database Dependency

## Data Type Mapping

| IotDB Data type | SeaTunnel Data type |
|-----------------|---------------------|
| BOOLEAN | BOOLEAN |
| INT32 | TINYINT |
| INT32 | SMALLINT |
| INT32 | INT |
| INT64 | BIGINT |
| FLOAT | FLOAT |
| DOUBLE | DOUBLE |
| TEXT | STRING |

## Sink Options

| Name | Type | Required | Default | Description |
|-----------------------------|---------|----------|--------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| node_urls | Array | Yes | - | `IoTDB` cluster address, the format is `["host:port", ...]` |
| username | String | Yes | - | `IoTDB` user username |
| password | String | Yes | - | `IoTDB` user password |
| key_device | String | No | - | Specify field name of the `IoTDB` deviceId in SeaTunnelRow |
| key_timestamp | String | No | processing time | Specify field-name of the `IoTDB` timestamp in SeaTunnelRow. If not specified, use processing-time as timestamp |
| key_measurement_fields | Array | No | exclude `device` & `timestamp` | Specify field-name of the `IoTDB` measurement list in SeaTunnelRow. If not specified, include all fields but exclude `device` & `timestamp` |
| storage_group | Array | No | - | Specify device storage group(path prefix) <br/> example: deviceId = ${storage_group} + "." + ${key_device} |
| batch_size | Integer | No | 1024 | For batch writing, when the number of buffers reaches the number of `batch_size` or the time reaches `batch_interval_ms`, the data will be flushed into the IoTDB |
| max_retries | Integer | No | - | The number of retries to flush failed |
| retry_backoff_multiplier_ms | Integer | No | - | Using as a multiplier for generating the next delay for backoff |
| max_retry_backoff_ms | Integer | No | - | The amount of time to wait before attempting to retry a request to `IoTDB` |
| default_thrift_buffer_size | Integer | No | - | Thrift init buffer size in `IoTDB` client |
| max_thrift_frame_size | Integer | No | - | Thrift max frame size in `IoTDB` client |
| zone_id | string | No | - | java.time.ZoneId in `IoTDB` client |
| enable_rpc_compression | Boolean | No | - | Enable rpc compression in `IoTDB` client |
| connection_timeout_in_ms | Integer | No | - | The maximum time (in ms) to wait when connecting to `IoTDB` |
| common-options | | no | - | Sink plugin common parameters, please refer to [Sink Common Options](common-options.md) for details |