Is there a way to reset yesterday's (and/or today's) energy usage on the Sonoff Pow? #406

Closed
mihalski opened this issue May 3, 2017 · 3 comments
Labels
enhancement Type - Enhancement that will be worked on

Comments

@mihalski
Copy link

mihalski commented May 3, 2017

As the topic states, is there a way to reset yesterday's (and/or today's) energy usage on the Sonoff Pow?

Or is the only way to just wait it out?

@arendst
Copy link
Owner

arendst commented May 5, 2017

Will be available in next release.

@arendst arendst added the enhancement Type - Enhancement that will be worked on label May 5, 2017
@mihalski
Copy link
Author

mihalski commented May 5, 2017

That's great! Thank you.

arendst added a commit that referenced this issue May 5, 2017
5.0.4 20170505
* Add Sonoff Pow Energy Total up to 40 MWh
* Add command EnergyReset 1|2|3 to reset Energy counters (#406)
* Fix Domoticz Energy logging (#411)
* Add command PowerOnState 4 to keep relay always on and disabling all
power control (#418)
@mihalski
Copy link
Author

mihalski commented May 5, 2017

Thank you kindly.

@mihalski mihalski closed this as completed May 5, 2017
arendst added a commit that referenced this issue Nov 21, 2017
5.9.1g
 * Fix typo ALIRFRCV into ARIRFRCV
 * Add nicer clock support for
larger hand widths
 * Add better clock support for different pixel
counts (#1226)
 * Remove command EnergyReset 1..3
 * Add commands
EnergyReset1 0..42500, EnergyReset2 0..42500 and EnergyReset3
0..42500000
 *  to (Re)set Energy Today, Yesterday or Total respectively
in Wh (#406, #685, #1202)
 * Add SettingsSaveAll routine to command
SaveData to be used before controlled power down (#1202)
arendst added a commit that referenced this issue Dec 1, 2017
5.10.0 20171201
 * Upgrade library ArduinoJson to 5.11.2
 * Upgrade
library IRRemoteEsp8266 to 2.2.1 + 2 commits but disabled some protocols
(code size reduction)
 * Upgrade library NeoPixelBus to 2.2.9
 * Upgrade
library OneWire to 2.3.3 + 6 commits and disabled CRC lookup-table
(#define ONEWIRE_CRC8_TABLE 0) (code size reduction)
 * Update library
PubSubClient to 2.6 + 9 commits and additional delay (#790)
 * Update
core_esp8266_wiring_digital.c to latest (staged) level
 * Patch library
I2Cdevlib-Core for esp8266-core 2.4.0-rc2 compatibility
 * Remove
command EnergyReset 1..3 now replaced by ENergyReset1 to EnergyReset3
 *
Remove spaces in JSON messages (code size reduction)
 * Renamed
xsns_05_ds18x20.ino to xsns_05_ds18x20_legacy.ino still using library
OneWire and providing dynamic sensor scan
 * Fix possible iram1_0_seg
compile error by shrinking ICACHE_RAM_ATTR code usage
 * Fix PWM
watchdog timeout if Dimmer is set to 100 or Color set to 0xFF (#1146)
 *
Fix Sonoff Bridge Learn Mode hang caused by unrecognised RF code
(#1181)
 * Fix blank console log window by using XML character encoding
(#1187)
 * Fix wrong response name for command HlwISet (#1214)
 * Fix
DHT type sensor timeout recognition by distinguish "signal already
there" from "timeout" (#1233)
 * Add fixed color options 1..12 to
command Color
 * Add + (plus) and - (minus) to commands Dimmer
(+10/-10), Speed and Scheme
 * Add + (plus) and - (minus) to command
Color to select 1 out of 12 preset colors
 * Add + (plus) and - (minus)
to command Ct to control ColdWarm led ColorTemperature (+34/-34)
 * Add
commands EnergyReset1 0..42500, EnergyReset2 0..42500 and EnergyReset3
0..42500000
 *  to (Re)set Energy Today, Yesterday or Total respectively
in Wh (#406, #685, #1202)
 * Add optional ADS1115 driver as alternative
for unsupported I2Cdevlib in esp8266-core 2.4.0-rc2
 * Add support for
INA219 Voltage and Current sensor to be enabled in user_config.h with
define USE_INA219
 * Add support for Arilux LC11 (Clearing RF home code
when selecting no Arilux module)
 * Add support for WS2812 RGBW
ledstrips to be enabled in user_config.h with define USE_WS2812_CTYPE
(#1156)
 * Add SettingsSaveAll routine to command SaveData to be used
before controlled power down (#1202)
 * Add option PUSHBUTTON_TOGGLE
(SwitchMode 7) to allow toggling on any switch change (#1221)
 * Add new
xdrv_05_ds18x20.ino free from library OneWire and add the following
features:
 *  Add support for DS1822
 *  Add forced setting of 12-bit
resolution for selected device types (#1222)
 *  Add read temperature
retry counter (#1215)
 *  Fix lost sensors by performing sensor probe at
restart only thereby removing dynamic sensor probe (#1215)
 *  Fix
sensor address sorting using ascending sort on sensor type followed by
sensor address
 *  Rewrite JSON resulting in shorter message allowing
more sensors in default firmware image:
 *
"DS18B20-1":{"Id":"00000483C23A","Temperature":19.5},"DS18B20-2":{"Id":"0000048EC44C","Temperature":19.6}

* Add additional define in user_config.h to select either single sensor
(defines disabled), new multi sensor (USE_DS18X20) or legacy multi
sensor (USE_DS18X20_LEGACY)
 * Add clock support for more different
pixel counts (#1226)
 * Add support for Sonoff Dual R2 (#1249)
 * Add
FriendlyName to web page tab and add program information to web page
footer (#1275)
curzon01 pushed a commit to curzon01/Tasmota that referenced this issue Sep 6, 2018
5.0.4 20170505
* Add Sonoff Pow Energy Total up to 40 MWh
* Add command EnergyReset 1|2|3 to reset Energy counters (arendst#406)
* Fix Domoticz Energy logging (arendst#411)
* Add command PowerOnState 4 to keep relay always on and disabling all
power control (arendst#418)
curzon01 pushed a commit to curzon01/Tasmota that referenced this issue Sep 6, 2018
5.9.1g
 * Fix typo ALIRFRCV into ARIRFRCV
 * Add nicer clock support for
larger hand widths
 * Add better clock support for different pixel
counts (arendst#1226)
 * Remove command EnergyReset 1..3
 * Add commands
EnergyReset1 0..42500, EnergyReset2 0..42500 and EnergyReset3
0..42500000
 *  to (Re)set Energy Today, Yesterday or Total respectively
in Wh (arendst#406, arendst#685, arendst#1202)
 * Add SettingsSaveAll routine to command
SaveData to be used before controlled power down (arendst#1202)
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
enhancement Type - Enhancement that will be worked on
Projects
None yet
Development

No branches or pull requests

2 participants