Yes, for individual changes the fexc is the right pointer, and I have of course been using it for testing the LEDs' polarities. |
I don't get what you want. You want me to write something different into a fex file? What do you expect that happens then: https://github.com/O-Computers/linux-sunxi/blob/h3/drivers/leds/leds-sunxi.c#L77 It would be better if you come up with a working example (both code and explanation what has changed) |
Sorry for possibly having bothered you, Thomas. Feel free to ignore the topic, and enjoy your vacation. My question has been answered: The change was done on purpose for having the green LED act as Power indicator. And it does not only affect the Orange Pi PC, but is an intended functional change for multiple boards. So there is no reason to change anything. In my previous post I just wanted to point out that inverting the LED polarity might break (at least affect) some use-cases of the LED triggers (/sys/class/leds/...), e.g. "mmc0" trigger. Therefore I suggested to turn on the LED not by inverting its polarity, but by using other means to set its GPIO pin early during boot-up. So that the user does not have to deal with the inverted logic if he wants to use the LED for other purposes later on during runtime. Most users won't care about the LEDs, so this might not seem like an issue, I admit. Just recently I discovered the LED triggers and use them now as the primary system status feedback (PPP and SSH tunnel Go/NoGo signalling on red, mmc0 status on green) for my offsite server. OK, no problem. I will just adapt everything to my personal preferences. |
Sorry, I still don't get what you want. We just exchanged red and green, the triggers remained the same:
What's your proposal? Which change where should bring which benefit? I just checked it (built extra an image from scratch) and I can set every of the above triggers from user space regardless of the defaults we use/changed. Or is the problem that there aren't that much triggers available as with sun7i (A20)? |
Yes, of course you can use them, but the polarity differs from the user's expectation. The user might expect to have the "natural" polarity. That is, he wants the LED to go off if he sets the brightness setting to 0 (just one example) and vice versa. Now, what happens to the green LED when you set its trigger to "default-on"? It switches off, right? That's what I mean. It's not what the user expects. And it renders most triggers useless as they are supposed to let the LED light up when something interesting is happening, not to go out. My suggestion was simply to switch the LED on during boot (e.g., by assigning "default-on" as the default trigger), but leave the active level at its natural position (as wired on the PCB). I see that this is not possible with the current implementation of leds-sunxi.c, unfortunately. It seems the Cubieboard has a more advanced version of that driver, but I doubt that I find the time to have a closer look at it. |
Thx for being more precise. Not I get what's wrong. Only applies to the green led where brightness and none|default-on have reversed meaning. The red one is not affected. Since all we did is just change the role of both leds in script.bin I would suspect that's a driver issue. Well let's try it out:
Nope, breaks everything :) |
What do you mean by driver issue? I don't see any. Everything works as designed. You've changed the definition of the active state for the green LED, therefore it always behaves contrary to the commanded state. |
I think I understand now. Changed the definition (have a look in the middle of this commit) and tried to solve the problem that the green led now would be active even after a shutdown with redefining it to heartbeat in |
Thanks for your work! Haven't applied it yet, but the changeset seems very promising. Didn't know that it's that easy to set the default level (I'm talking about the <1> instead of <0> in the fex). Else I would have suggested it right from the start. |