Update HI vtx smearing according to new beta*. #11141
Update HI vtx smearing according to new beta*. #11141
Conversation
A new Pull Request was created by @mandrenguyen for CMSSW_7_5_X. Update HI vtx smearing according to new beta*. It involves the following packages: Configuration/StandardSequences @cmsbuild, @civanch, @franzoni, @mdhildreth, @davidlange6 can you please review it and eventually sign? Thanks. |
please test |
+1 |
The tests are being triggered in jenkins. |
@davidlange6 |
Update HI vtx smearing according to new beta*.
The beam conditions expected for the PbPb run have been changed.
See Tiziano's slides from the WGM:
https://indico.cern.ch/event/442020/contribution/0/attachments/1148526/1647556/WGM241.pdf
This PR updates the beta*.
I also took the opportunity to shift the beamspot centroid to the current pp locations.
Last time around in 2011, the centroid stayed fairly close between pp and PbPb, so this should be a better assumption than the origin.
This new vertex smearing is not the default, so there will be no change in relval.
We propose to switch this to the default when we reevaluate the reco beamspot and update the GT in a PR to come shortly, once we can produce some samples with this vertex smearing.
A 76X PR was also made #11138