75X - Fix for handling of rare cases of CSC CFEB data corruptions with incorrect 16 samples flag reporting #12187
75X - Fix for handling of rare cases of CSC CFEB data corruptions with incorrect 16 samples flag reporting #12187
Conversation
…h incorrect 16 samples flag reporting
A new Pull Request was created by @barvic for CMSSW_7_5_X. 75X - Fix for handling of rare cases of CSC CFEB data corruptions with incorrect 16 samples flag reporting It involves the following packages: EventFilter/CSCRawToDigi @cmsbuild, @cvuosalo, @slava77 can you please review it and eventually sign? Thanks. |
@cmsbuild please test |
The tests are being triggered in jenkins. |
+1 Bug fix to handle rare cases of CSC CFEB data corruption. There should be no change in monitored quantities. #12186, #12188, and #12190 are the 74X, 76X, and 80X versions of this PR. #12186 has already been approved by Reco. The code fix is satisfactory, and Jenkins tests against baseline CMSSW_7_5_X_2015-10-29-1100 show no significant differences, as expected. The fix was verified for #12186. |
This pull request is fully signed and it will be integrated in one of the next CMSSW_7_5_X IBs (tests are also fine) and once validation in the development release cycle CMSSW_7_6_X is complete. This pull request requires discussion in the ORP meeting before it's merged. @davidlange6, @Degano, @smuzaffar |
+1 |
75X - Fix for handling of rare cases of CSC CFEB data corruptions with incorrect 16 samples flag reporting
75X - Fix for handling of rare cases of CSC CFEB data corruptions with incorrect 16 samples flag reporting.
Refer to https://hypernews.cern.ch/HyperNews/CMS/get/recoDevelopment/1395.html thread.
74X - PR 74X - Fix for handling of rare cases of CSC CFEB data corruptions withh incorrect 16 sample flag reporting #12186