Notifications
You must be signed in to change notification settings - Fork 0
Automatically manage fan duty for Clevo-type notebooks using Linux kernels EC interface
License
joshuabach/clevo-fan
Folders and files
Name | Name | Last commit message | Last commit date | |
---|---|---|---|---|
Repository files navigation
clevo-fan - Automatically manage fan duty Inspired by: https://github.com/SkyLandTW/clevo-indicator You probably need to `modprobe ec_sys` before running. This periodicaly reads the core temperature from the kernels EC interface and updates the fan duty based on it. Different policies, implemented as mathematic functions are available, to determine the fan duty. Some options can be used to try to remove temporary spikes from and generally smoothen the temperature before calulating the fan duty based on it. This helps reduce fluctuation in the fan activity. Some options also directly affect the fan curve. Once the fan control loop is running, this command won't fail. Every error is handled, so that the fan never gets unattended: When failing to read the temperature, an infinitely high temperature is assumed to stay on the safe side. When the fan duty cannot be set, the cycle is skipped and setting it is tried again using the next queried temperature. All these error conditions are reported to stderr. Any errors writing to stderr (or to stdout) are ignored. USAGE: clevo-fan auto [FLAGS] [OPTIONS] --exp --linear --square FLAGS: --exp Determine fan duty as an exponential function of the core temperature -h, --help Prints help information --linear Determine fan duty as a linear function of the core temperature --monitor Monitor temperature and fan duty curves --square Determine fan duty as a quadratic function of the core temperature -V, --version Prints version information OPTIONS: --exp-base <exp-base> Set base of the fan duty function [default: e] [possible values: 2, e] --exp-factor <exp-factor> Set fan duty factor for exponential function [default: 1] --linear-offset <linear-offset> Set y-axis offset of the fan duty function [default: 0.0] --linear-slope <linear-slope> Set slope of the fan duty function [default: 1.0] --max-unchanged-cycles <max-unchanged-cycles> Maximum number of consequtive fan duty changes to ignore [default: 10] --min-fan-change <min-fan-change> Only apply fan duty changes smaller than this value [default: 0.0] -a, --moving-average <moving-average> Apply moving average to temperature curve -m, --moving-median <moving-median> Apply moving median to temperature curve -i, --polling-interval <polling-interval> Update interval, in milliseconds [default: 500] --square-factor <square-factor> Set fan duty factor for square function [default: 0.01]
About
Automatically manage fan duty for Clevo-type notebooks using Linux kernels EC interface
Resources
License
Stars
Watchers
Forks
Releases
No releases published