When the application network configuration fails validation, the
AppNetworkStatus
will be marked with an error, while theAppNum
andMACGenerator
fields will remain unset. If the user corrects the invalid part of the configuration, thehandleAppNetworkModify
callback will be triggered, and validation will succeed. However, before activating the application network, the zedrouter must ensure thatAppNum
andMACGenerator
are initialized. Otherwise, zedbox process will panic with a fatal error:undefined MAC generator
Issue addressed by this patch was introduced in version 11.5.0