periph.io/x/devices/v3/bmxx80: add support for filters without using SenseContinuous #74

Merged
merged 1 commit into from
Sep 4, 2024
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
2 changes: 1 addition & 1 deletion bmxx80/bmx280.go
Original file line number Diff line number Diff line change
Expand Up @@ -75,7 +75,7 @@ const (
// measurements are done.
type standby uint8

// Possible standby values, these determines the refresh rate.
// Possible standby values, these determine the refresh rate.
const (
s500us standby = 0
s10msBME standby = 6
Expand Down
4 changes: 2 additions & 2 deletions bmxx80/bmx280_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -7,7 +7,7 @@ package bmxx80
import (
"errors"
"flag"
"io/ioutil"
"io"
"log"
"os"
"testing"
Expand Down Expand Up @@ -1028,7 +1028,7 @@ func (s *spiFail) Connect(f physic.Frequency, mode spi.Mode, bits int) (spi.Conn
func TestMain(m *testing.M) {
flag.Parse()
if !testing.Verbose() {
log.SetOutput(ioutil.Discard)
log.SetOutput(io.Discard)
}
os.Exit(m.Run())
}
46 changes: 30 additions & 16 deletions bmxx80/bmxx80.go
Original file line number Diff line number Diff line change
Expand Up @@ -138,9 +138,12 @@ type Opts struct {
// Humidity sensing is only supported on BME280. The value is ignored on other
// devices.
Humidity Oversampling
// Filter is only used while using SenseContinuous() and is only supported on
// BMx280.
// Filter is only used while using SenseContinuous() or with a pre-set standby duration
// It is only supported on BMx280.
Filter Filter
// Standby Used with Filter to control the time between samples.
// If this is set we enable the filter on device creation and set the device mode to normal instead of sleep.
Standby time.Duration
}

func (o *Opts) delayTypical280() time.Duration {
Expand Down Expand Up @@ -236,18 +239,21 @@ func (d *Dev) Sense(e *physic.Env) error {
}

if d.is280 {
err := d.writeCommands([]byte{
// ctrl_meas
0xF4, byte(d.opts.Temperature)<<5 | byte(d.opts.Pressure)<<2 | byte(forced),
})
if err != nil {
return d.wrap(err)
}
doSleep(d.measDelay)
for idle := false; !idle; {
if idle, err = d.isIdle280(); err != nil {
// Skip setting mode to forced if we are already in normal mode
if d.opts.Filter == NoFilter || d.opts.Standby == 0 {
err := d.writeCommands([]byte{
// ctrl_meas
0xF4, byte(d.opts.Temperature)<<5 | byte(d.opts.Pressure)<<2 | byte(forced),
})
if err != nil {
return d.wrap(err)
}
doSleep(d.measDelay)
for idle := false; !idle; {
if idle, err = d.isIdle280(); err != nil {
return d.wrap(err)
}
}
}
return d.sense280(e)
}
Expand Down Expand Up @@ -388,6 +394,14 @@ func (d *Dev) makeDev(opts *Opts) error {
}
}
d.cal280 = newCalibration(tph[:], h[:])
standbyDuration := s1s
filter := NoFilter
startingMode := sleep
if d.opts.Filter != NoFilter && d.opts.Standby != 0 {
standbyDuration = chooseStandby(d.isBME, d.opts.Standby)
filter = d.opts.Filter
startingMode = normal
}
var b []byte
if d.isBME {
b = []byte{
Expand All @@ -398,9 +412,9 @@ func (d *Dev) makeDev(opts *Opts) error {
// ctrl_hum
0xF2, byte(d.opts.Humidity),
// config
0xF5, byte(s1s)<<5 | byte(NoFilter)<<2,
0xF5, byte(standbyDuration)<<5 | byte(filter)<<2,
// As per page 25, ctrl_meas must be re-written last.
0xF4, byte(d.opts.Temperature)<<5 | byte(d.opts.Pressure)<<2 | byte(sleep),
0xF4, byte(d.opts.Temperature)<<5 | byte(d.opts.Pressure)<<2 | byte(startingMode),
}
} else {
// BMP280 doesn't have humidity to control.
Expand All @@ -410,9 +424,9 @@ func (d *Dev) makeDev(opts *Opts) error {
// into normal but was not Halt'ed.
0xF4, byte(d.opts.Temperature)<<5 | byte(d.opts.Pressure)<<2 | byte(sleep),
// config
0xF5, byte(s1s)<<5 | byte(NoFilter)<<2,
0xF5, byte(standbyDuration)<<5 | byte(filter)<<2,
// As per page 25, ctrl_meas must be re-written last.
0xF4, byte(d.opts.Temperature)<<5 | byte(d.opts.Pressure)<<2 | byte(sleep),
0xF4, byte(d.opts.Temperature)<<5 | byte(d.opts.Pressure)<<2 | byte(startingMode),
}
}
return d.writeCommands(b)
Expand Down
2 changes: 1 addition & 1 deletion bmxx80/doc.go
Original file line number Diff line number Diff line change
Expand Up @@ -32,6 +32,6 @@
//
// The results of the calculations in the algorithm on page 15 are partly
// wrong. It looks like the original authors used non-integer calculations and
// some nubers were rounded. Take the results of the calculations with a grain
// some numbers were rounded. Take the results of the calculations with a grain
// of salt.
package bmxx80