2foc.3.3.38: solves the overcurrent problem #551

Merged
merged 1 commit into from
Jan 9, 2025

Conversation

ale-git
Copy link
Contributor

@ale-git ale-git commented Jan 8, 2025

It solves the overcurrent problem by disabling the current sensor gain calibration at startup.

@ale-git ale-git requested a review from marcoaccame January 8, 2025 09:11
@ale-git ale-git self-assigned this Jan 8, 2025
Current sensor gain calibration at startup removed.
@marcoaccame marcoaccame changed the title 2foc.3.3.38 2foc.3.3.38: solves the overcurrent problem Jan 9, 2025
Copy link
Contributor

@marcoaccame marcoaccame left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

ok, thanks

@marcoaccame marcoaccame merged commit cf69040 into robotology:master Jan 9, 2025
Nicogene added a commit to robotology/robotology-superbuild that referenced this pull request Jan 9, 2025
The patch has been bumped for icub-firmware and icub-firmware-build, for including:
- robotology/icub-firmware-build#187
- robotology/icub-firmware#551
traversaro pushed a commit to robotology/robotology-superbuild that referenced this pull request Jan 9, 2025
The patch has been bumped for icub-firmware and icub-firmware-build, for including:
- robotology/icub-firmware-build#187
- robotology/icub-firmware#551