-
Notifications
You must be signed in to change notification settings - Fork 1
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Fix plot detections and reprojections function #42
Merged
Conversation
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
…leap-anipose into eric/calibration-imgs
Closed
Closed
sean-afshar
reviewed
Jun 5, 2024
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Looks good
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
The problem in Issue #41 was caused by a mismatch between the number of frames in the video and the length of the frames list input into the make_reproj_imgs() function. In my tests, I noticed that earlier sample frames seemed to match, while later sampled frames did not match. This is because each of the frames that lead to no detections would be subtracted from the list of total frames. So they become progressively more mismatched. The good news however is that the calibration itself was not compromised by this bug just the plotting. So calibration files should be good to go, and histograms remain an accurate representation of the error.
I have written a new version of the make_reproj_imgs() function which grabs the frame from the video using imageio and ffmpeg rather than from a list of images. The eric/calibration-imgs branch eliminates the problem of misaligned detections, reprojections and images described in Issue #41.