Describe the bug I we try to store data which exceeds the available size the NVS settings backend returns success but fails in real.
To Reproduce Call: settings_save_one( path, p_data, INT_MAX ) Tested on: nrf52840dk_nrf52840 with SETTINGS_NVS enabled
Expected behavior The function: settings_nvs_save() should return failure code but instead it returns ok.
Impact Unit tests are not passing: nrfconnect/sdk-nrf#3806
Logs and console output
Environment (please complete the following information):
Additional context This PR fixes the bug: #31870
The text was updated successfully, but these errors were encountered:
Successfully merging a pull request may close this issue.
Describe the bug
I we try to store data which exceeds the available size the NVS settings backend returns success but fails in real.
To Reproduce
Call: settings_save_one( path, p_data, INT_MAX )
Tested on: nrf52840dk_nrf52840 with SETTINGS_NVS enabled
Expected behavior
The function: settings_nvs_save() should return failure code but instead it returns ok.
Impact
Unit tests are not passing: nrfconnect/sdk-nrf#3806
Logs and console output
Environment (please complete the following information):
Additional context
This PR fixes the bug: #31870