When viewing a measurement on an NAC/No PT weight in TMTV mode the units of the measurement are displayed as "RAW" instead of prop counts/BQML as they are in Basic Mode.
select the NAC and draw the same ellipse and the units will be in Propcounts
The current behavior
The units displayed for PET images which are not SUV calculable (no patient weight or uncorrected) are displaying measurements in "RAW"
The expected behavior
The units displayed for PET images which are not SUV calculable (no patient weight or uncorrected) should be displayed in whatever units are listed in the dicom meta data under the "units" tag. PROPCOUNTS for most NAC and BQML for most PET AC, This is the behaviour in basic mode
OS
windows
Node version
OHIF demo
Browser
Both Edge Version 118.0.2088.76 (Official build) (64-bit) and Chrome Version 118.0.5993.118 (Official Build) (64-bit)
The text was updated successfully, but these errors were encountered:
Yes this specific bug still exists on dev viewer.
Open the water phantom in TMTV, drag the NAC onto the PET section, use the measurement tool, units show as RAW.
linearbot
changed the title
Units displayed as RAW in TMTV mode rather than PROPCNTS[Bug]
Units displayed as RAW in TMTV mode rather than PROPCNTS[Bug]
Nov 6, 2024
Describe the Bug
When viewing a measurement on an NAC/No PT weight in TMTV mode the units of the measurement are displayed as "RAW" instead of prop counts/BQML as they are in Basic Mode.
On OHIF demo : https://viewer.ohif.org/tmtv?StudyInstanceUIDs=1.3.6.1.4.1.14519.5.2.1.7009.2403.871108593056125491804754960339
In TMTV mode


In Basic mode
On OHIF demo/local with a PET AC with no patient weight:


In TMTV mode
In Basic Mode
Steps to Reproduce
eg https://viewer.ohif.org/tmtv?StudyInstanceUIDs=1.3.6.1.4.1.14519.5.2.1.7009.2403.871108593056125491804754960339
https://viewer.ohif.org/viewer?StudyInstanceUIDs=1.3.6.1.4.1.14519.5.2.1.7009.2403.871108593056125491804754960339
The current behavior
The units displayed for PET images which are not SUV calculable (no patient weight or uncorrected) are displaying measurements in "RAW"
The expected behavior
The units displayed for PET images which are not SUV calculable (no patient weight or uncorrected) should be displayed in whatever units are listed in the dicom meta data under the "units" tag. PROPCOUNTS for most NAC and BQML for most PET AC, This is the behaviour in basic mode