A new Pull Request was created by @kpedro88 (Kevin Pedro) for master. It involves the following packages: CalibCalorimetry/HcalAlgos @perrotta, @ghellwig, @civanch, @arunhep, @cerminar, @cmsbuild, @franzoni, @mdhildreth, @slava77, @mmusich, @kpedro88, @davidlange6 can you please review it and eventually sign? Thanks. cms-bot commands are listed here #13028 |
@cmsbuild please test |
The tests are being triggered in jenkins. |
@@ -90,3 +93,6 @@ | |||
|
|||
# Disable the "triangle peak fit" and the corresponding HBHETriangleNoise flag | |||
hbheprereco.pulseShapeParametersQIE8.TrianglePeakTS = cms.uint32(10000) | |||
|
|||
from Configuration.Eras.Modifier_phase2_hcal_cff import phase2_hcal | |||
phase2_hcal.toModify(hbheprereco, saveEffectivePedestal = cms.bool(True)) |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@kpedro88 is this propagated also into the hltHbhereco ?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I doubt it, but for phase2 I'm not sure if it matters...
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Nope, you were right. Testing a fix now...
-1 Tested at: 16be266 You can see the results of the tests here: I found follow errors while testing this PR Failed tests: UnitTests RelVals AddOn
I found errors in the following unit tests: ---> test testRecoMETMETProducers had ERRORS
When I ran the RelVals I found an error in the following worklfows: runTheMatrix-results/4.22_RunCosmics2011A+RunCosmics2011A+RECOCOSD+ALCACOSD+SKIMCOSD+HARVESTDC/step2_RunCosmics2011A+RunCosmics2011A+RECOCOSD+ALCACOSD+SKIMCOSD+HARVESTDC.log101.0 step1 runTheMatrix-results/101.0_SingleElectronE120EHCAL+SingleElectronE120EHCAL/step1_SingleElectronE120EHCAL+SingleElectronE120EHCAL.log5.1 step1 runTheMatrix-results/5.1_TTbar+TTbarFS+HARVESTFS/step1_TTbar+TTbarFS+HARVESTFS.log140.53 step2 runTheMatrix-results/140.53_RunHI2011+RunHI2011+RECOHID11+HARVESTDHI/step2_RunHI2011+RunHI2011+RECOHID11+HARVESTDHI.log135.4 step1 runTheMatrix-results/135.4_ZEE_13+ZEEFS_13+HARVESTUP15FS+MINIAODMCUP15FS/step1_ZEE_13+ZEEFS_13+HARVESTUP15FS+MINIAODMCUP15FS.log1000.0 step2 runTheMatrix-results/1000.0_RunMinBias2011A+RunMinBias2011A+TIER0+SKIMD+HARVESTDfst2+ALCASPLIT/step2_RunMinBias2011A+RunMinBias2011A+TIER0+SKIMD+HARVESTDfst2+ALCASPLIT.log8.0 step3 runTheMatrix-results/8.0_BeamHalo+BeamHalo+DIGICOS+RECOCOS+ALCABH+HARVESTCOS/step3_BeamHalo+BeamHalo+DIGICOS+RECOCOS+ALCABH+HARVESTCOS.log1003.0 step2 runTheMatrix-results/1003.0_RunMinBias2012A+RunMinBias2012A+RECODDQM+HARVESTDDQM/step2_RunMinBias2012A+RunMinBias2012A+RECODDQM+HARVESTDDQM.log1001.0 step2 runTheMatrix-results/1001.0_RunMinBias2011A+RunMinBias2011A+TIER0EXP+ALCAEXP+ALCAHARVD1+ALCAHARVD2+ALCAHARVD3+ALCAHARVD4+ALCAHARVD5/step2_RunMinBias2011A+RunMinBias2011A+TIER0EXP+ALCAEXP+ALCAHARVD1+ALCAHARVD2+ALCAHARVD3+ALCAHARVD4+ALCAHARVD5.log4.53 step3 runTheMatrix-results/4.53_RunPhoton2012B+RunPhoton2012B+HLTD+RECODR1reHLT+HARVESTDR1reHLT/step3_RunPhoton2012B+RunPhoton2012B+HLTD+RECODR1reHLT+HARVESTDR1reHLT.log10042.0 step2 runTheMatrix-results/10042.0_ZMM_13+ZMM_13TeV_TuneCUETP8M1_2017_GenSimFull+DigiFull_2017+RecoFull_2017+ALCAFull_2017+HARVESTFull_2017/step2_ZMM_13+ZMM_13TeV_TuneCUETP8M1_2017_GenSimFull+DigiFull_2017+RecoFull_2017+ALCAFull_2017+HARVESTFull_2017.log1306.0 step3 runTheMatrix-results/1306.0_SingleMuPt1_UP15+SingleMuPt1_UP15+DIGIUP15+RECOUP15+HARVESTUP15/step3_SingleMuPt1_UP15+SingleMuPt1_UP15+DIGIUP15+RECOUP15+HARVESTUP15.log1330.0 step3 runTheMatrix-results/1330.0_ZMM_13+ZMM_13+DIGIUP15+RECOUP15+HARVESTUP15/step3_ZMM_13+ZMM_13+DIGIUP15+RECOUP15+HARVESTUP15.log10024.0 step2 runTheMatrix-results/10024.0_TTbar_13+TTbar_13TeV_TuneCUETP8M1_2017_GenSimFull+DigiFull_2017+RecoFull_2017+ALCAFull_2017+HARVESTFull_2017/step2_TTbar_13+TTbar_13TeV_TuneCUETP8M1_2017_GenSimFull+DigiFull_2017+RecoFull_2017+ALCAFull_2017+HARVESTFull_2017.log10824.0 step2 runTheMatrix-results/10824.0_TTbar_13+TTbar_13TeV_TuneCUETP8M1_2018_GenSimFull+DigiFull_2018+RecoFull_2018+ALCAFull_2018+HARVESTFull_2018/step2_TTbar_13+TTbar_13TeV_TuneCUETP8M1_2018_GenSimFull+DigiFull_2018+RecoFull_2018+ALCAFull_2018+HARVESTFull_2018.log9.0 step3 runTheMatrix-results/9.0_Higgs200ChargedTaus+Higgs200ChargedTaus+DIGI+RECO+HARVEST/step3_Higgs200ChargedTaus+Higgs200ChargedTaus+DIGI+RECO+HARVEST.log20034.0 step3 runTheMatrix-results/20034.0_TTbar_14TeV+TTbar_14TeV_TuneCUETP8M1_2023D7_GenSimHLBeamSpotFull14+DigiFullTrigger_2023D7+RecoFullGlobal_2023D7+HARVESTFullGlobal_2023D7/step3_TTbar_14TeV+TTbar_14TeV_TuneCUETP8M1_2023D7_GenSimHLBeamSpotFull14+DigiFullTrigger_2023D7+RecoFullGlobal_2023D7+HARVESTFullGlobal_2023D7.log136.731 step3 runTheMatrix-results/136.731_RunSinglePh2016B+RunSinglePh2016B+HLTDR2_2016+RECODR2_2016reHLT_skimSinglePh_HIPM+HARVESTDR2/step3_RunSinglePh2016B+RunSinglePh2016B+HLTDR2_2016+RECODR2_2016reHLT_skimSinglePh_HIPM+HARVESTDR2.log50202.0 step3 runTheMatrix-results/50202.0_TTbar_13+TTbar_13+DIGIUP15_PU50+RECOUP15_PU50+HARVESTUP15_PU50/step3_TTbar_13+TTbar_13+DIGIUP15_PU50+RECOUP15_PU50+HARVESTUP15_PU50.log25.0 step3 runTheMatrix-results/25.0_TTbar+TTbar+DIGI+RECOAlCaCalo+HARVEST+ALCATT/step3_TTbar+TTbar+DIGI+RECOAlCaCalo+HARVEST+ALCATT.log25202.0 step3 runTheMatrix-results/25202.0_TTbar_13+TTbar_13+DIGIUP15_PU25+RECOUP15_PU25+HARVESTUP15_PU25/step3_TTbar_13+TTbar_13+DIGIUP15_PU25+RECOUP15_PU25+HARVESTUP15_PU25.log21234.0 step3 runTheMatrix-results/21234.0_TTbar_14TeV+TTbar_14TeV_TuneCUETP8M1_2023D4_GenSimHLBeamSpotFull14+DigiFullTrigger_2023D4+RecoFullGlobal_2023D4+HARVESTFullGlobal_2023D4/step3_TTbar_14TeV+TTbar_14TeV_TuneCUETP8M1_2023D4_GenSimHLBeamSpotFull14+DigiFullTrigger_2023D4+RecoFullGlobal_2023D4+HARVESTFullGlobal_2023D4.log23234.0 step3 runTheMatrix-results/23234.0_TTbar_14TeV+TTbar_14TeV_TuneCUETP8M1_2023D8_GenSimHLBeamSpotFull14+DigiFullTrigger_2023D8+RecoFullGlobal_2023D8+HARVESTFullGlobal_2023D8/step3_TTbar_14TeV+TTbar_14TeV_TuneCUETP8M1_2023D8_GenSimHLBeamSpotFull14+DigiFullTrigger_2023D8+RecoFullGlobal_2023D8+HARVESTFullGlobal_2023D8.log
I found errors in the following addon tests: cmsDriver.py TTbar_8TeV_TuneCUETP8M1_cfi --conditions auto:run1_mc --fast -n 100 --eventcontent AODSIM,DQM --relval 100000,1000 -s GEN,SIM,RECOBEFMIX,DIGI:pdigi_valid,L1,DIGI2RAW,L1Reco,RECO,EI,VALIDATION --customise=HLTrigger/Configuration/CustomConfigs.L1THLT --datatier GEN-SIM-DIGI-RECO,DQMIO --beamspot Realistic8TeVCollision : FAILED - time: date Wed Mar 29 15:24:50 2017-date Wed Mar 29 15:23:40 2017 s - exit: 18688 |
Comparison not run due to runTheMatrix errors (RelVals and Igprof tests were also skipped) |
@cmsbuild please test |
The tests are being triggered in jenkins. |
The tests are being triggered in jenkins. |
Comparison job queued. |
+1 |
Comparison is ready Comparison Summary:
|
@davidlange6 please merge this ASAP |
+1 |
@davidlange6 ping |
+1 |
The new aging features introduced in this PR are primarily intended to be used for HB Phase2 TDR studies, but can also be used for nearer-term HE studies.
Scintillator radiation damage:
HBHEDarkening
,HBHERecalibration
HBHEDarkeningAnalyzer
prints out darkening and recalibration factors for given lumi:SiPM radiation damage:
HcalSiPMRadiationDamage
HBHEPhase1Reconstructor
to account for dark current contribution to pedestal mean (only enabled for phase2), eventually this can be redone in a better way - attn: @abdoulline, @igv4321, @mariadalfonsoAdd aging and recalibration to cmsRun config:
NOTA BENE model parameters in Python are NOT final and may change, depending on ongoing studies!
See presentation in last week's upgrade studies meeting; a more in-depth presentation will be given during upcoming CMS week.