Notifications
You must be signed in to change notification settings - Fork 6
Auto Increment Capacity
Thomas Shone edited this page Sep 18, 2021
·
1 revision
Operational
Auto incrementing columns have an upper limit based on their data type. As tables grow there is a chance that the field will run out of capacity and INSERTs will start failing. This can result in outages and long locking times while you attempt to correct the problem.
When you run out of capacity, you will need to ALTER
the column to a large size.
# Original table design
CREATE TABLE t1 (
id MEDIUMINT UNSIGNED AUTO_INCREMENT,
email VARCHAR(255) NOT NULL,
PRIMARY KEY id
);
# Increase the capacity of the field
ALTER TABLE t1
MODIFY COLUMN id INT UNSIGNED AUTO_INCREMENT;
-
AUTO_INCREMENT
fields do not wrap. - Altering a large table can result in it locking up for an extended period of time. If you're unable to take the table offline to perform this operation, consider using a tool like Online Schema Change to avoid downtime.