Addressing #3085. If the
target_temperature
is set directly it never invokes or disables the timer set instart_watching_heater
, so after stopping a print or turning off all heaters you could get a “Heating failed” error.This fixes the issue by using
setTargetHotend(n, 0)
indisable_all_heaters
instead of settingtarget_temperature[n] = 0
directly.